How To's

How to run CODA

How to perform online analysis

How to open the online scaler screen - xscaler

How to open the high voltage GUI

How to check the Raster/BPM pattern

How to check the MLU settings

How to bring up the Beamtime Accounting Table

How to change the momentum setting of the HRS

How to set trigger prescale factors

DVCS How To's























How to run CODA

How to perform online analysis

  1. Login as a-onl on one of the analysis machines - aonl1, aonl2, or aonl3 (e.g. "ssh a-onl@aonl2").

  2. Type "goonlana" - this will take you to the online analysis directory (/adaqfs/home/a-onl/gmp/replay).

How to open the online scaler screen - xscaler

How to open the high voltage GUI (for all detectors)

How to Check the Raster/BPM Pattern

  1. Login as a-onl on aonl1 (i.e "ssh a-onl@aonl1").

  2. Start a new coda run. (How to run CODA)

  3. Type "spot_L" to check the Raster/BPM on the Left HRS and "spot_R" on the Right HRS. This will check the data for the most recent run. If you wish to check an earlier run, add the run number after the command (e.g. spot_L 10189).

How to check the MLU settings

  1. Login to the adaq1 or adaq2 machine as user atrig (e.g. ssh atrig@adaq1).

  2. Type "trigsetup".

  3. Check the settings for both the LEFT HRS MLU and the RIGHT HRS MLU in the GUI which appears. Set each MLU to the correct mode (i.e singles mode or GMP standard mode), and make sure all trigger channels are enabled.

  4. Click the quit button.

How to bring up the Beamtime Accounting Table

  1. Login to the adaq1 machine as user "adaq".

  2. type "bta". (See here for more information.)

How to change the momentum setting of the HRS

  1. Go to the Hall A Tools (HAC) window.

  2. To lower the spectrometer momentum, simply set the momentum in the P0 SET field. The curents on the magnets will adjust automatically. For the LHRS, an additional step is needed to set the Q1 momentum (Refer to the DVCS documentation for additional information on this).

  3. To increase the spectrometer momentum, you need to cycle the Q2 and Q3 magnets first and then enter the desired momentum setting. To cyle the Q2 and Q3, turn off their regulation (button next to P0 SET ), set Q2 and Q3 to 1600 A (button next I(A) field), wait two minutes at 1600A, set the p0 to the desired value, and turn on the Q2 and Q3 regulations.

How to set trigger prescale factors

  1. For the LEFT HRS, open a terminal in the adaq1 machine and type prescaleL. For the RIGHT HRS, open a terminal in the adaq2 machine and type prescaleR.

  2. Set the appropriate prescale factor for each trigger in the GUI which appears.

  3. Click the "save" button to save any changes.