User name apar
Log entry time 11:59:55 on May 22, 2003
Entry number 103289
keyword=End_of_Parity_Run_3152__CODA_Config=GDH
End-of-Parity-run EPICS data for Run Number 3152 at Thu May 22 11:59:43 EDT 2003
CODA Configuration: GDH
# Timing board information: # Integrate Time = 2.45 ms, Ramp Delay = 0.00 us oversamp 13
Wien angle : 30.1995
Wien BDL : 697.8
Wien field : 20.052
Laser attenuation Hall A : 100
Laser power Hall A : 69
Beam Half-wave plate Set(off=out) : IN
Beam Half-wave plate Read(off=out) : IN
Rotating waveplate : 1500
IA Cell Setpoint Hall A : 9.86598
PZT X Setpoint Hall A : 5
PZT Y Setpoint Hall A : 5
PZT X Setpoint Common : 5
PZT Y Setpoint Common : 5
Gun2: PC (PITA) POS : 7.178
Gun2: PC (PITA) NEG : 7.503
G0 Helicity Settle Set : 500 usec
G0 Helicity Delay Set : 8 cycles
G0 Helicity Pattern Set : Quartet
G0 Helicity Random/Toggle Set : Random
G0 Helicity Settle Read : 500 usec
G0 Helicity Delay Read : 8 cycles
G0 Helicity Pattern Read : Quartet
G0 Helicity Random/Toggle Read : Random
Parity DAQ Feedback Control(1=on) : 1
IA Feedback Control Hall A : enabled
IA Charge Asymmetry Hall A : -54.68
IA Timestamp Hall A : 1053618188
IA Slope Hall A : -408
LUMI 1 HV - Ch 10 : -1101.3
LUMI 2 HV - Ch 11 : -1001.2
LUMI 3 HV - Ch 6 : -500.7
LUMI 4 HV - Ch 7 : -799.7
Left Arm arm angle : 18.0002
Right Arm arm angle : 12.5016
Left Arm arm mispointing (HPT) : -0
Right Arm arm mispointing (HPT) : -0
Left Arm Q1 momentum : 1.85513
Left Arm Q2 power supply current : 798.757
Left Arm Q2 momentum : 1.85499
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 626.597
Left Arm D1 momentum : 1.85503
Left Arm D1 NMR : 0.686459
Left Arm Q3 power supply current : 738.566
Left Arm Q3 momentum : 1.85514
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 1.87686
Right Arm Q1 gauss meter : -0.02798
Right Arm Q2 power supply current : 936.388
Right Arm Q2 momentum : 2.15783
Right Arm Q2 gauss meter : 0.4919
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 648.941
Right Arm D1 momentum : 1.8768
Right Arm D1 NMR : 0.696458
Right Arm Q3 power supply current : 878.89
Right Arm Q3 momentum : 1.87681
Right Arm Q3 gauss meter : 0.3942
Right Arm Q3 power supply polarity : disabled
Left Arm Top VDC Current : -2.49023
Left Arm Bottom VDC Current : 3.27148
Left Arm Top VDC voltage : 4.00391
Left Arm Bottom VDC voltage : 3.9917
Right Arm Top VDC voltage : 3.99463
Right Arm Bottom VDC voltage : 3.9917
Average current of the two cavities : 0.0159934
Current on Unser monitor : -15.8846
Current on Upstream bcm : 0.0164414
Current on Downstream bcm : 0.0155454
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143715
Tiefenbach Hall A energy : 3324.92
Tiefenbach Hall C energy : 5497.99
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3330.15
MBSY3c Hall C Beam energy : 5513.38
MBSY1c magnet current (amp) : 138.683
MBSY1c Bdl : 831044
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Arc1 dp/p : 0.000295633
Arc2 dp/p : 0.000917756
Left Arm Collimator : 0.0647949
HacL_HPE1313A:0_Ch58 : -0.14209
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.102539
Right Arm Collimator : -0.000488281
Right LVDT HPM : 3289
Right LVDT VPM : 3881
HacR_HPE1313A:0_Ch58 : -0.547363
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.883301
HacR_alignROLL : 0.466989
HacR_alignPITCH : -0.489172
HacR_alignHPT : -0
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -33.9
Right Arm Scattering Angle : 12.5016
Target OTR x-position : 0.0502024
Target OTR y-position : -0.872528
Target OTR x-width : 2.68714
Target OTR y-width : 2.55829
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : -10.5973
Arc OTR y-position : 5.10482
Arc OTR x-width : 0
Arc OTR y-width : -0
Arc OTR data valid flag : No
Arc OTR In/Out : Current is Low
Polarized 3He Target Position : Empty Target
Polarized 3He Target RTD #1 : 44.1602
Polarized 3He Target RTD #2 : 37.4023
Polarized 3He Target RTD #3 : 44.6875
Polarized 3He Target RTD #4 : 46.6504
Polarized 3He Target RTD #5 : 49.0527
Polarized 3He Target RTD #6 : 198.516
Polarized 3He Target RTD #7 : 181.055
Polarized 3He Ref. Cell RTD #8 : 25.166
Polarized 3He Ref. Cell RTD #9 : 25.1562
Polarized 3He Ref. Cell RTD #10 : 25.166
Polarized 3He Target Ref. Cell Gas Pres. : -26.0059
Polarized 3He Target Ref. Cell Sys.Vac. : 6.2341
Polarized 3He Target Cooling Jet : 57.8796
Polarized 3He Target OVEN RTD : 169.8
Polarized 3He Target OVEN SP1 SET : 170
Polarized 3He Target OVEN SP1 : 170
Polarized 3He Target OVEN AL1 SET : 0
Polarized 3He Target OVEN AL1 : 0
Polarized 3He Target OVEN AL1 STATUS : enabled
Polarized 3He Target Half-Wave Plate DIST: 1.2e+06
Polarized 3He Target Half-Wave Plate STAT: 1200000
Polarized 3He Target Position (PA) : 9.0945
Polarized 3He Target Position (POS) : Empty Target
Polarized 3He Target Position (DA) : 9.0946
Polarized 3He Target Position (SS9) : Axis is OK
Polarized 3He Target Position (SA10) : 0
Polarized 3He Target Position (SA9) : 0
Polarized 3He Laser#1 State : 0
Polarized 3He Laser#1 Current : 36
Polarized 3He Laser#1 Temperature : 15.3
Polarized 3He Laser#2 State : 0
Polarized 3He Laser#2 Current : 41.4
Polarized 3He Laser#2 Temperature : 7.2
Polarized 3He Laser#3 State : 0
Polarized 3He Laser#3 Current : 38.1
Polarized 3He Laser#3 Temperature : 10.8
Polarized 3He Laser#4 State : 2
Polarized 3He Laser#4 Current : 38
Polarized 3He Laser#4 Temperature : 14.3
Polarized 3He Laser#5 State : 2
Polarized 3He Laser#5 Current : 18
Polarized 3He Laser#5 Temperature : 29
Polarized 3He Laser#6 State : 2
Polarized 3He Laser#6 Current : 38.1
Polarized 3He Laser#6 Temperature : 10
Polarized 3He Laser#7 State : 2
Polarized 3He Laser#7 Current : 40
Polarized 3He Laser#7 Temperature : 9.8
Polarized 3He Coil Current Longitudinal : -6.912
Polarized 3He Coil Current Transverse : -0.046