• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 10:02:44 on August 31, 1999

    Entry number 26660

    keyword=End_of_Run_1642
    ****************************
     Run Number: 1642
    End of Run Comment:
    Tar=LD2-15cm,Type=Inelastic,Pmom=1.133,Rad=0,Ene=1.667,Angle_e=42.66,Angle_h=33.88
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  6193.5159  Hz     |    6187.8804 Hz   |  6191.2055 Hz
        2      |  514.07946  Hz     |    513.1225 Hz   |  513.68781 Hz
        3      |  45649.128  Hz     |    45620.142 Hz   |  45640.211 Hz
        4      |  38253.828  Hz     |    38220.608 Hz   |  38245.12 Hz
        5      |  48.437794  Hz     |    48.346692 Hz   |  48.364776 Hz
        output |  78.744114  Hz   |    78.126451 Hz |  78.460604 Hz
     Total number of output triggers =     2.77106e+05 
     Number of raw T1 21866008.0  ; Number of raw T3 1.6119142e+08
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 58.863087 min
     Time of run h- = 28.990608 min
     Time of run h+ = 28.990103 min
     1-(sum of time hel + and -)/( run time) = 1.4990e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.500173  Hz         |    0.0 Hz        |  15.000063 Hz
          -        |  0.0  Hz        |    15.000063 Hz       |  15.000346 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0610621         |   0.0610200         | 0.1239580     
       upstream 3x |   0.0612498         |   0.0612081         | 0.1243403     
       upstream 10x|   0.0615368         |   0.0614939         | 0.1249222     
      downstream   |   0.0610988         |   0.0610565         | 0.1240325    
     downstream 3x |   0.0613326         |   0.0612917         | 0.1245086    
     downstream 10x|   0.0613805         |   0.0613384         | 0.1246052    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -3.44849900e-04 
       upstream 3x |   -3.40525190e-04 
       upstream 10x|   -3.48693460e-04 
      downstream   |   -3.46280510e-04 
     downstream 3x |   -3.33539110e-04 
     downstream 10x|   -3.43060440e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1642 at Tue Aug 31 10:02:42 EDT 1999
    Electron Q1 power supply current        : 848.4
    Electron Q1 momentum                    : 1.1339
    Electron Q1 gauss meter                 : -0.072
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 485.545
    Electron Q2 momentum                    : 1.1338
    Electron Q2 gauss meter                 : 0.2564
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 376.226
    Electron D1 momentum                    : 1.13401
    Electron D1 NMR                         : 0.417521
    Electron Q3 power supply current        : 449.028
    Electron Q3 momentum                    : 1.13408
    Electron Q3 gauss meter                 : -0.2233
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 847.28
    Hadron Q1 momentum                      : 1.133
    Hadron Q1 gauss meter                   : 0.021464
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 485.153
    Hadron Q2 momentum                      : 1.1335
    Hadron Q2 gauss meter                   : -0.25557
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 386.029
    Hadron D1 momentum                      : 1.133
    Hadron D1 NMR                           : 0.418142
    Hadron Q3 power supply current          : 448.478
    Hadron Q3 momentum                      : 1.13329
    Hadron Q3 gauss meter                   : -0.20104
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 36.7269
    Current on Unser monitor                : 31.1118
    Current on Upstream bcm                 : 36.9266
    Current on Downstream bcm               : 36.5272
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1669.16