    User name a-onl

    Log entry time 14:08:06 on March 15, 2002

    Entry number 1761

    keyword=End_of_Run_4224
    ****************************
     Run Number: 4224
     End of Run Comment:
    Run_type=optics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=kinematics 17, optics, 25 micro-A, FR off prescale 1/50/20/1000/1, UNBUFF,daq_mode=coincidence,leftarm_p=1.741,leftarm_theta=22.66,photonarm_D=hrs,photonarm_angle=-20.43,photonarm_p=-3.145,target_name=15cm LH2,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=1   ps2=50   ps3=20   ps4=1000   ps5=1   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS[0]: 442433       [+]: 216811       [-]: 217160       
    TIME  [0]: 10.511 mins  [+]: 5.155 mins  [-]: 5.154 mins  
    LIVE  [0]:  85.48%      [+]:  85.38%      [-]:  85.57%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :394.5/394.5 Hz   T2[0] : 2.0/99.5 Hz   T3[0] :419.9/8397.9 Hz   T4[0] : 0.4/385.9 Hz   T5[0] : 3.9/3.9  Hz   T6[0] : 0.0/0.0  Hz   T7[0] : 0.0/0.0  Hz   T8[0] : 0.0/1024.0 Hz   
    T1[+] :394.5/394.5 Hz   T2[+] : 2.0/99.8 Hz   T3[+] :420.3/8405.5 Hz   T4[+] : 0.4/385.8 Hz   T5[+] : 3.9/3.9  Hz   T6[+] : 0.0/0.0  Hz   T7[+] : 0.0/0.0  Hz   T8[+] : 0.0/1024.0 Hz   
    T1[-] :394.7/394.7 Hz   T2[-] : 2.0/99.2 Hz   T3[-] :419.6/8393.0 Hz   T4[-] : 0.4/386.2 Hz   T5[-] : 3.9/3.9  Hz   T6[-] : 0.0/0.0  Hz   T7[-] : 0.0/0.0  Hz   T8[-] : 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] : 248806/248806   T2[0] :   1255/62752    T3[0] : 264799/5295999  T4[0] :    243/243371   T5[0] :   2476/2476     T6[0] :      0/0        T7[0] :      0/0        T8[0] :      9/645766   
    T1[+] : 122012/122012   T2[+] :    617/30866    T3[+] : 129992/2599857  T4[+] :    119/119318   T5[+] :   1204/1204     T6[+] :      0/0        T7[+] :      0/0        T8[+] :      4/316727   
    T1[-] : 122051/122051   T2[-] :    613/30684    T3[-] : 129772/2595451  T4[-] :    119/119420   T5[-] :   1216/1216     T6[-] :      0/0        T7[-] :      0/0        T8[-] :      4/316662   
    
    AVERAGE CURRENT
    BCM x1 : 18.3111uA  BCM x3 : 8.9617 uA  BCM x10: 18.3448uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    476.8 ppm     BCM u3 :    459.3 ppm     BCM u10:    461.2 ppm     
    BCM d1 :      477 ppm     BCM d3 :    1E+39 ppm     BCM d10:    457.4 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01128        BCM u3 [0]:0.01132        BCM u10[0]:0.01134        
    BCM u1 [+]:0.005538       BCM u3 [+]:0.005554       BCM u10[+]:0.005565       
    BCM u1 [-]:0.005531       BCM u3 [-]:0.005548       BCM u10[-]:0.005559       
    
    BCM d1 [0]:0.01181        BCM d3 [0]:-1.424E-05     BCM d10[0]:0.0118         
    BCM d1 [+]:0.005796       BCM d3 [+]:-6.989E-06     BCM d10[+]:0.005789       
    BCM d1 [-]:0.005789       BCM d3 [-]:-6.975E-06     BCM d10[-]:0.005783       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4224 at Fri Mar 15 14:08:00 EST 2002
    Left Arm D1 momentum : 1.74101
    Left Arm arm angle : 22.6625
    Tiefenbach Hall A energy : 5749.18
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.53906
    Left Arm Bottom VDC Current : 0.0488281
    Left Arm Q1 power supply current : 1309.7
    Left Arm Q1 momentum : 1.74085
    Left Arm Q1 gauss meter : 0.11139
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 749.616
    Left Arm Q2 momentum : 1.74086
    Left Arm Q2 gauss meter : -0.3952
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 586.112
    Left Arm D1 momentum : 1.74101
    Left Arm D1 NMR : 0.64429
    Left Arm Q3 power supply current : 693.216
    Left Arm Q3 momentum : 1.74123
    Left Arm Q3 gauss meter : 0.347
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 24.2793
    Current on Unser monitor : 31.7543
    Current on Upstream bcm : 24.1945
    Current on Downstream bcm : 24.3641
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 24.4766
    MBSY1c Hall A Beam energy : 5765.77
    MBSY1c magnet current (amp) : 241.034
    MBSY1c Bdl : 1.43885e+06
    MBSY3c Hall C Beam energy : 1204.48
    Tiefenbach Hall A energy : 5749.18
    Tiefenbach Hall C energy : 1201.48
    Delta(E)/E width (MV_AI_DXWID) : 0.151311
    IPM1C12.XPOS : 2.72115
    IPM1H04A.XPOS : 1.63406
    IPM1H04A.YPOS : 0.459882
    IPM1H04B.XPOS : 0.40323
    IPM1H04B.YPOS : -0.114257
    Left Arm Arm Collimator : 0.616992
    HacL_HPE1313A:0_Ch58 : -0.134277
    HacL_HPE1313A:0_Ch55 : 22.8516
    HacL_HPE1313A:0_Ch54 : -0.223145
    HacL_alignROLL : 0.134734
    HacL_alignPITCH : -0.12413
    HacL_alignHPT :
    Left Arm Arm Collimator : 0.616992
    Wien angle : 96.1695
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 2234.6
    Wien field : 64.112
    Laser attenuation Hall A : 246
    Laser power Hall A : 63
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : -0.751647
    Arc OTR y-position : 0.318975
    Arc OTR x-width : 4.40048
    Arc OTR y-width : 3.54618
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0