    The wien angle was changed to -61 during the last swing shift. But according to the spin calculator (monticella/injector), this is not the optimal setting for us (pol^2=0.16) and Hall C: Pol^2=0%. it's 100% in Hall B but hall B is down. We asked MCC to check this.