Log entry time 08:07:48 on November 15, 2010
Entry number 340149
keyword=Owl shift summary
November 15, 2010, Owl shift summary
Crew:
J. Roche (SL)
H. Albataineh (TO)
Highlights:
Smooth production on DVCS kine 3-low, hydrogen target
Timeline:
- 1:00: initial check out of configurations: DAQ configuration is
TrigDVCSNoC, 3A beam no raster, 15 cm LH2 target, beam position is
A(x,y)=0.0, -0.0, B(x,y)=0.0, 0.0. LHRS nmr locked, P0=1.864 GeV. HV
detectors are on, DC currents on calo are low (max value is
~0.16). Compton rates are amazingly low (~2.0 kHz/uA beam cavity on,
60 kHz/uA beam cavity off). T5 is not prescaled and rates
are ~147 Hz, deadtime ~15%.
- 2:45: MCC calls to report that the vacuum valves before and
after the target chamber tripped off (close) and then reset by
themselves after a few minutes. Indeed we are seeing an excursion in
the vacuum strip chart (halog). Beside
that nothing bips or looks strange, so we resume production. This
happened at the very end of run 8746.
- 3:05: Julie asks Hisham to take a ps9 only run (with
configuration TrigDVCSNoC), that was a bad idea, we should have gone
to LEFTHRS config, the DAQ hangs
up. Run 8747 and 8748 are junk. Had to restart coda, abandon this
little test.
Run list:
Run Events BCM U3 D3 (C) Time Avg Curr Deadtime
8744 626 k 0.01041 0.01134 60.1 mins 3.0132 uA 15.45%
8745 671 k 0.01108 0.01214 67.1 mins 2.8850 uA 13.98%
8746 558 k 0.00917 0.00998 59.2 mins 2.6953 uA 15.18%
8749 631 k 0.01050 0.01145 60.1 mins 3.0416 uA 15.96%
8750 620 k 0.01027 0.01125 60.6 mins 2.9586 uA 16.09%
8751 634 k 0.01055 0.01147 61.0 mins 3.0105 uA 16.09%
8752 593 k 0.00980 0.01068 61.2 mins 2.7861 uA 15.22%
8753 94 k 0.00156 0.00171 9.4 mins 2.8904 uA 17.07% (stopped early but good
anyway)
Compton Run list:
24008, 24009, 24010, 24011, 24012, 24013, 24014, 24015, 24016,
24017,24018, 24019, 24020.