• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name M Friend

    Log entry time 08:00:53 on December 7,2010

    Entry number 343147

    keyword=Owl shift summary

    Shift starting with efficiency run 9306

    12:23 - Moved to optics target for 30 minute optics run (run 9307).

    12:35 - Noticed fast feedback was turned off. Called MCC and had them turn it back on.

    01:00 - Done with optics run. Back to 15cm LD2 target and production running.

    01:50 - Bob called to say that the disk had become full (and, subsequently, the coda run crashed). Changed pingpong script to USEADAQL1=1. Restarted coda.

    05:55 - DVCS ioc crashed. Rebooted. Although the calorimeter PMT currents are now responding, the rates are still all zero, so rebooted a second time... Turns out the correct tab to look at on the scaler data GUI is the 4th one... the rates are fine there.

    06:56 - RF separator trip. Since there was a scheduled beam studies at 07:00 anyway, MCC will not bring the beam back up. Requested controlled access.

    07:55 - Hall in controlled access and ARM is starting the survey.



    Run Events BCM U3 D3 (C) Time Avg Curr Deadtime
    9308 908 k 0.00252 0.00250 43.1 mins 0.9725 uA 21.20% - disk became full and coda crashed during this run
    9309 1291 k 0.00358 0.00358 61.7 mins 0.9668 uA 22.73%
    9310 1289 k 0.00357 0.00356 63.6 mins 0.9350 uA 21.45%
    9311 1148 k 0.00318 0.00316 56.8 mins 0.9308 uA 20.94%
    9312 1185 k 0.00328 0.00327 56.8 mins 0.9607 uA 20.82%
    9313 42 k 0.00012 0.00012 2.0 mins 0.9607 uA 24.76% - DVCS ioc crashed
    9314 31 k 0.00008 0.00008 1.5 mins 0.9626 uA 26.30% - trouble rebooting ioc
    9315 899 k 0.00245 0.00243 59.5 mins 0.6852 uA 20.84%


    Efficiency run:
    9306 653 k 0.00180 0.00180 32.2 mins 0.9327 uA 13.13%

    Optics run:
    9307 206 k 0.00526 0.00525 30.9 mins 2.8316 uA 7.01%