We use local helicity control board for testing the asymmetry in happex crate and scaler, and use happex timing board DAC to generate 600ppm asymmetry signal(1.254344V for +helicity and 1.25282V for -), use attenuator box fan module to generate 5.3% asymmetry signal(568mV for + and 632mV for -), both happex and scaler can get right asymmetry value, shown in attachment.We can let hallC to do the same test.
local helicity control board setting: Mode:Free Clock T_Settle:70us T_Stable:1000us Helicity Pattern:Quartet Delay:8 windows
Injector helicity control board setting: Mode:Free Clock T_Settle:70us T_Stable:971.65us Helicity Pattern:Quartet Delay:8 windows
happex_left_upstream_asym
happex_left_downstream_asym
happex_right_upstream_asym
happex_right_downstream_asym
scaler_right_upstream_asym
scaler_right_downstream_asym