• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name pzhu

    Log entry time 23:03:54 on March 9,2012

    Entry number 365155

    keyword=new beam center check:A(-0.1,2.0),B(-1.6,0)

    Since chicane setting is changed, I check the beam position in target again.
    we use 100nA CW beam first,slow raster is 1.5V, target position is 3942550,beam position is A(-2.4,3.5),B(-4.1,1.5),run number is 3003
    Then we changed the beam position to A(-0.7,3.),B(-2.4,0.6),run is 3004
    Then we changed to A(-0.01,3),B(-0.9,0.6)run is 3005(in data1)
    Then we changed target position to 4091425, slow raster size to 1.1V,beam current to 50nA CW,run is 3005(in data2)
    Then we changed beam position to A(-0.01,4.2),B(-1.6,2),run is 3008
    Then we changed to A(-0.1,2.0),B(-1.6,-0.2),run is 3010
    We are in the center of the target, for new chicane setting the center position is A(-0.1,2.0),B(-1.6,0)
    Before setting is A(-0.3,-1.4),B(-1.1,-2.7)


    FIGURE 1