• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name M. Cummings

    Log entry time 16:05:04 on March 11, 2012

    Entry number 365722

    keyword=Day Shift Summary

    Day Shift Summary
    
    Shift Crew:
    SL: Melissa Cummings
    TO: Ryan Duve
    3rd: Garrett Josemans
    
    
    08:00 Start of shift, still taking GEp production data.
    08:45 Stop beam so target experts can do a target anneal
    09:00 Called for controlled access for target anneal.
    10:20 Target anneal is complete, hall is back in beam permit.  Waiting
    for the target fridge to fill with helium
    10:45 Polarizing the top cup of the target 
    11:15 Beam is back, resuming with GEp production
    11:30 Beam is stopped.  MCC says the A2 interception is high and they
    need to do some steering at the injector to adjust.  
    11:40 Beam is back, resuming production.
    12:15 Polarization lost on target due to 0.5A loss in magnet current. 
    Magnet was ramped back up and polarization recovered. 
    12:20 Asked MCC for bleedthrough check.  Their test indicated no
    bleedthrough current but Hall A 1H00 BCM still reads 2-3nA, even when
    beam is off to halls B&C.  
    12:40 Resume production
    04:00 Smooth data taking for the past 3.5 hours, plan is to continue
    taking GEp production data.
    
    
    Runs Taken: (LHRS/RHRS/TA)
    
    3084/22172/40310: Production (IHWP OUT), 3rd arm run now has correct
    prescales.
    3085/22173      : Production (IHWP OUT), beam stopped part way through
    the run
    3086/22174/40311: Production (IHWP OUT), beam trip partway through run
    3087/22175/40316: Production (IHWP OUT), ROC 26 rebooted on the RHRS
    during 22175, beam trip during run 3087
    3088/22177/40318: Production (IHWP OUT), beam trip partway through
    3089/22178      : Production (IHWP OUT)
    3090/22179/40319: Production (IHWP OUT)
    3091/22180/40320: Production (IHWP OUT)
    3092/22181/40321: Production (IHWP OUT)
    
    
    note: Runs 3085-3089, 22173-22178, 40311-40318 have the wrong label for
    target type: should be NH3 TOP