    keyword=How to Set Event Limits for CODA

    With the upgrade of the AFECS software, we can now set event limits for the
    left and right HRS run control GUI's.  Here are the instructions on how
    to do this procedure:
    
    1) From the rcGUI "Options" menu select "Scheduler" and then "Program".
    2) You can change the "Event Limit" by sliding the scroll bar to the desired 
    setting or by typing in the desired value in the white box.  If you use 
    the white box, make sure you press enter to record the value.
    3) Next press the "Set" button.  The window will close automatically.
    
    On the main rcGUI screen, the "Event Limit" field will now have the set
    point that you have selected, and the background of this field will now be
    yellow.
    
    One can also set a time limit in the third field up to 600 minutes.  Also
    it is possible to take multiple runs with the same event and time limits, 
    i.e., CODA will stop and start the runs automatically.  
    
    Currently I have set the event limit field to be 7 million events for 
    both spectrometers.  I have left the other fields set to zero for the 
    "Number of Runs" and the "Time Limit".  If CODA is restarted, then the 
    default limit of zero will be used for all three fields.
    


    A copy of this log entry has been emailed to: pzhu,jixie,rbziel,melissac,rom,camsonne,jmaxwell,jpchen,slifer,doug