User name V. Sulkosky
Log entry time 21:17:53 on April 22, 2012
Entry number 377646
This entry is a followup to: 377621
Followups:
keyword=[Techs] CO2 Gas Pressure
The last time the CO2 gas pressure indicated a positive value as
auto-logged every four hours was right after midnight this morning. After
that the value has been between -65 and -99 psi. Interesting the reading
is green and not red. Also the alarm panel in the Counting House should
be going off. That being said that does not mean that there is sufficient
CO2 gas for the Cherenkovs.
The shift crew should monitor the Gas Cherenkov ADC spectra for both HRS's
to ensure that the performance is still good.
A copy of this log entry has been emailed to: segal,slifer,jpchen,melissac,rshneor,camsonne