• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 21:38:29 on August 3, 1999

    Entry number 24186

    keyword=End_of_Run_690
    ****************************
     Run Number: 690
    End of Run Comment:
    Tar=BeO,Type=Cosmic,Pmom=2000,Rad=0,Ene=4000,Angle_e=12.54,Angle_h=12.53
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  4.2558541  Hz     |    4.0835418 Hz   |  4.1749318 Hz
        2      |  10.760737  Hz     |    10.312673 Hz   |  10.496971 Hz
        3      |  4.3250549  Hz     |    3.7720852 Hz   |  4.0045264 Hz
        4      |  703.42693  Hz     |    699.1508 Hz   |  701.81455 Hz
        5      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        output |  8.580909  Hz   |    7.9940521 Hz |  8.2476203 Hz
     Total number of output triggers =     4.84000e+02 
     Number of raw T1 245.0  ; Number of raw T3 235.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 0.9780599 min
     Time of run h- = 0.48160807 min
     Time of run h+ = 0.48168945 min
     1-(sum of time hel + and -)/( run time) = 1.5094e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.4978366  Hz         |    0.0 Hz        |  15.012714 Hz
          -        |  0.0  Hz        |    14.995673 Hz       |  15.012714 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0001381         |   0.0001382         | 0.0002805     
       upstream 3x |   0.0001391         |   0.0001392         | 0.0002826     
       upstream 10x|   0.0001403         |   0.0001404         | 0.0002851     
      downstream   |   0.0001381         |   0.0001382         | 0.0002805    
     downstream 3x |   0.0001394         |   0.0001395         | 0.0002832    
     downstream 10x|   0.0001397         |   0.0001398         | 0.0002838    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   3.61925440e-04 
       upstream 3x |   3.59324470e-04 
       upstream 10x|   3.56252230e-04 
      downstream   |   3.61925440e-04 
     downstream 3x |   3.58551450e-04 
     downstream 10x|   3.57781750e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 690 at Tue Aug  3 21:38:27 EDT 1999
    Electron Q1 power supply current        : 703.885
    Electron Q1 momentum                    : 0.940751
    Electron Q1 gauss meter                 : -0.05976
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 402.84
    Electron Q2 momentum                    : 0.940678
    Electron Q2 gauss meter                 : 0.213
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 311.982
    Electron D1 momentum                    : 0.940996
    Electron D1 NMR                         : 0.346496
    Electron Q3 power supply current        : 372.564
    Electron Q3 momentum                    : 0.940959
    Electron Q3 gauss meter                 : -0.18556
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 492.135
    Hadron Q1 momentum                      : 0.658091
    Hadron Q1 gauss meter                   : 0.012538
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 281.464
    Hadron Q2 momentum                      : 0.657605
    Hadron Q2 gauss meter                   : -0.14754
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 225.427
    Hadron D1 momentum                      : 0.658
    Hadron D1 NMR                           : 0.24284
    Hadron Q3 power supply current          : 260.329
    Hadron Q3 momentum                      : 0.65784
    Hadron Q3 gauss meter                   : -0.11634
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 4.88502
    Current on Unser monitor                : -2.03703
    Current on Upstream bcm                 : 4.90125
    Current on Downstream bcm               : 4.86879
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1148.17