• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 05:29:55 on August 28, 1999

    Entry number 26435

    keyword=End_of_Run_1552
    ****************************
     Run Number: 1552
    End of Run Comment:
    Tar=LH2-15cm,Type=Inelastic,Pmom=0.6946,Rad=0,Ene=1.667,Angle_e=24.453,Angle_h=58.971
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  13765.856  Hz     |    13760.617 Hz   |  13765.125 Hz
        2      |  166.00405  Hz     |    167.3018 Hz   |  166.68874 Hz
        3      |  3367.4785  Hz     |    3353.8477 Hz   |  3360.8585 Hz
        4      |  3385.6827  Hz     |    3385.682 Hz   |  3386.2087 Hz
        5      |  2200.0876  Hz     |    2193.467 Hz   |  2196.7497 Hz
        output |  1768.5641  Hz   |    1764.2571 Hz |  1766.2436 Hz
     Total number of output triggers =     1.50808e+06 
     Number of raw T1 11753172.0  ; Number of raw T3 2869625.0
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 14.230615 min
     Time of run h- = 7.0086913 min
     Time of run h+ = 7.0084635 min
     1-(sum of time hel + and -)/( run time) = 1.5000e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5014326  Hz         |    0.0 Hz        |  15.002865 Hz
          -        |  0.0  Hz        |    15.001694 Hz       |  15.002865 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0017108         |   0.0017095         | 0.0034724     
       upstream 3x |   0.0017253         |   0.0017238         | 0.0035020     
       upstream 10x|   0.0017420         |   0.0017404         | 0.0035357     
      downstream   |   0.0017155         |   0.0017142         | 0.0034820    
     downstream 3x |   0.0017342         |   0.0017327         | 0.0035201    
     downstream 10x|   0.0017383         |   0.0017368         | 0.0035283    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -3.80083620e-04 
       upstream 3x |   -4.34896060e-04 
       upstream 10x|   -4.59453250e-04 
      downstream   |   -3.79041900e-04 
     downstream 3x |   -4.32663190e-04 
     downstream 10x|   -4.31642250e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1552 at Sat Aug 28 05:29:53 EDT 1999
    Electron Q1 power supply current        : 1075.9
    Electron Q1 momentum                    : 1.43795
    Electron Q1 gauss meter                 : -0.09118
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 615.9
    Electron Q2 momentum                    : 1.4382
    Electron Q2 gauss meter                 : 0.3247
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 478.998
    Electron D1 momentum                    : 1.43801
    Electron D1 NMR                         : 0.529329
    Electron Q3 power supply current        : 569.461
    Electron Q3 momentum                    : 1.43825
    Electron Q3 gauss meter                 : -0.2828
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 519.365
    Hadron Q1 momentum                      : 0.694504
    Hadron Q1 gauss meter                   : 0.013288
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 297.307
    Hadron Q2 momentum                      : 0.694622
    Hadron Q2 gauss meter                   : -0.1574
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 235.539
    Hadron D1 momentum                      : 0.6946
    Hadron D1 NMR                           : 0.256348
    Hadron Q3 power supply current          : 274.739
    Hadron Q3 momentum                      : 0.694255
    Hadron Q3 gauss meter                   : -0.12374
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 4.14476
    Current on Unser monitor                : -1.68862
    Current on Upstream bcm                 : 4.15116
    Current on Downstream bcm               : 4.13836
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1669.15