• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 00:47:30 on August 31, 1999

    Entry number 26641

    keyword=End_of_Run_1631
    ****************************
     Run Number: 1631
    End of Run Comment:
    Tar=LD2-15cm,Type=Inelastic,Pmom=1.133,Rad=0,Ene=1.667,Angle_e=42.66,Angle_h=33.88
    
    
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  6444.5163  Hz     |    6438.3096 Hz   |  6441.7773 Hz
        2      |  552.80644  Hz     |    551.42142 Hz   |  552.00909 Hz
        3      |  47415.985  Hz     |    47389.329 Hz   |  47403.033 Hz
        4      |  39932.64  Hz     |    39910.701 Hz   |  39925.653 Hz
        5      |  52.584128  Hz     |    52.757791 Hz   |  52.628056 Hz
        output |  84.064017  Hz   |    84.201712 Hz |  84.129614 Hz
     Total number of output triggers =     2.37159e+05 
     Number of raw T1 18159188.0  ; Number of raw T3 1.3362781e+08
     (The raw T1,T3 has to be corrected for deadtime)
     Time of run = 46.982862 min
     Time of run h- = 23.139078 min
     Time of run h+ = 23.139112 min
     1-(sum of time hel + and -)/( run time) = 1.4998e-02
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  7.5013169  Hz         |    0.0 Hz        |  15.002989 Hz
          -        |  0.0  Hz        |    15.002989 Hz       |  15.002989 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0507384         |   0.0507006         | 0.1029837     
       upstream 3x |   0.0508916         |   0.0508544         | 0.1032970     
       upstream 10x|   0.0511248         |   0.0510865         | 0.1037691     
      downstream   |   0.0507677         |   0.0507301         | 0.1030435    
     downstream 3x |   0.0509565         |   0.0509200         | 0.1034296    
     downstream 10x|   0.0509914         |   0.0509538         | 0.1034992    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -3.72637740e-04 
       upstream 3x |   -3.65616340e-04 
       upstream 10x|   -3.74713950e-04 
      downstream   |   -3.70451380e-04 
     downstream 3x |   -3.58276930e-04 
     downstream 10x|   -3.68825600e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1631 at Tue Aug 31 00:47:28 EDT 1999
    Electron Q1 power supply current        : 848.4
    Electron Q1 momentum                    : 1.1339
    Electron Q1 gauss meter                 : -0.07198
    Electron Q1 power supply polarity       : 0
    Electron Q2 power supply current        : 485.626
    Electron Q2 momentum                    : 1.13399
    Electron Q2 gauss meter                 : 0.2564
    Electron Q2 power supply polarity       : 1
    Electron D1 power supply current        : 376.225
    Electron D1 momentum                    : 1.13401
    Electron D1 NMR                         : 0.417521
    Electron Q3 power supply current        : 448.805
    Electron Q3 momentum                    : 1.13351
    Electron Q3 gauss meter                 : -0.2232
    Electron Q3 power supply polarity       : 1
    Hadron Q1 power supply current          : 847.315
    Hadron Q1 momentum                      : 1.13304
    Hadron Q1 gauss meter                   : 0.021469
    Hadron Q1 power supply polarity         : 1
    Hadron Q2 power supply current          : 484.95
    Hadron Q2 momentum                      : 1.13303
    Hadron Q2 gauss meter                   : -0.25553
    Hadron Q2 power supply polarity         : 1
    Hadron D1 power supply current          : 386.024
    Hadron D1 momentum                      : 1.133
    Hadron D1 NMR                           : 0.418142
    Hadron Q3 power supply current          : 448.416
    Hadron Q3 momentum                      : 1.13313
    Hadron Q3 gauss meter                   : -0.20105
    Hadron Q3 power supply polarity         : 0
    Average current of the two cavities     : 40.2906
    Current on Unser monitor                : 34.2837
    Current on Upstream bcm                 : 40.3547
    Current on Downstream bcm               : 40.2264
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 77
    Beam energy                             : 1669.16