Counting Room Status (Hall A counting room must be manned.):
End station Status:
Items to check prior to securing the Hall for beam:
- Spectrometers
- [ ]
- correct angle
- [ ]
- correct pointing
- [ ]
- turbo on at turbo controller in rack 1H71/72B08
- [ ]
- blower on at controls under spectrometer
- [ ]
- pump valves open at valve controller in rack 1H71/72B08 switch --
- [ ]
- convectron gages read "0" microns
- [ ]
- cold cathode gages on at gage in rack -- cold cathode <5x10-5
- [ ]
- windows functional
- Target
- [ ]
- correct target
- [ ]
- correct types
- [ ]
- cctv cameras on and focused
- [ ]
- target light on
- [ ]
- turbo on at rack -----
- [ ]
- turbo valve open at rack ------ switch ----
- [ ]
- backing pump on
- [ ]
- gages operational
- [ ]
- convectron "0" microns
- [ ]
- cold cathode <5x10-4
- [ ]
- windows functional
- Magnets
- [ ]
- set lead flows on Q1 to approx. SLPM, He
- [ ]
- set lead flows on Q2 to approx. SLPM, He
turn on lead heaters
set lead flows on Q3 to approx. -----SLPM, He
turn on lead heaters
- [ ]
- set lead flows on Dipole to approx. SLPM, He
- [ ]
- visual inspection of main current leads, dump resistor, and lead flags (for
- [ ]
- condition, visual shorts, etc.)
- [ ]
- full of liquid
- [ ]
- correct LCW flow and pressure (100 psi supply and 60 psi return)
- [ ]
- red rotating beacons on
- [ ]
- Power Supplies
- [ ]
- on and in remote control operational
- Exit beam tube
- [ ]
- turbo on at rack ------
- [ ]
- backing pump on and operational
- [ ]
- valve open controlled at rack ------ switch -----
- [ ]
- gages operational
- [ ]
- convectron "0" microns
- Entrance beam tube
- [ ]
- beam line vacuum valves OPEN
- [ ]
- instrument air compressor functioning normally
- Dump
- [ ]
- water if necessary
- [ ]
- He flow
- [ ]
- dump wall closed
- Detectors
- [ ]
- Electron HRS VDC gas flow
- [ ]
- Electron HRS HV on
- [ ]
- Hadron HRS VDC gas flow
- [ ]
- Hadron HRS HV on
- [ ]
- Hadron FPP gas flow
- Gas Shed
- [ ]
- Argon supply
- [ ]
- Ethane supply
- The Hall
- [ ]
- all interlocks in rack ----- indicate green
- [ ]
- cctv cameras on and focused
- [ ]
- clear of unnecessary equipment
- [ ]
- Man lift and Forklift in truck ramp
- [ ]
- unnecessary personnel exit Hall
- [ ]
- Doors closed and locked
Signature Date
Next: 4.7.2.4 Check List -
Previous: Independent Verification - Hall A
10/13/1997