Personnel safety system (PSS) console equipment is located in the main
control room. It includes:
- Access control
- Safety interlock
- ODH monitoring
- Radiation monitoring
- Public address system.
Table 2.2:
Hall A Beamline Elements (continued)
ARC SECTION
1C08 |
BPM |
|
|
IPM1C08 |
93.42465 |
|
|
Quad |
|
MQA1C08 |
93.05000 |
|
|
BC |
|
MBC1C08H |
92.70685 |
|
|
Sext |
|
MSA1C08 |
92.40500 |
|
TV View |
|
|
ITV1C08 |
92.21180 |
|
|
|
Ion Pump |
VIP1C08 |
|
1CB5 |
|
Dipole (3m) |
|
MBA1C05 |
90.30000 |
1C09 |
|
Quad |
|
MQA1C09 |
87.85000 |
|
|
BC |
|
MBC1C09H |
87.50685 |
|
|
Sext |
|
MSA1C09 |
87.20500 |
1CB6 |
|
Dipole (3m) |
|
MBA1C06 |
85.10000 |
1C10 |
BPM |
|
|
IPM1C10 |
83.02465 |
|
|
Quad |
|
MQA1C10 |
82.65000 |
|
|
BC |
|
MBC1C10H |
82.30685 |
|
|
Sext |
|
MSA1C10 |
82.00500 |
|
|
|
Ion Pump |
VIP1C10 |
81.81180 |
1CB7 |
|
Dipole (3m) |
|
MBA1C07 |
79.90000 |
1C11 |
|
Quad |
|
MQA1C11 |
77.45000 |
|
|
BC |
|
MBC1C11V |
77.10685 |
|
|
Sext |
|
MSA1C11 |
76.80500 |
|
|
|
Covectron |
VTC1C11 |
76.61180 |
1CB8 |
|
Dipole (3m) |
|
MBA1C08 |
74.70000 |
1C12 |
BPM |
|
|
IPM1C12 |
72.62465 |
|
|
Quad |
|
MQA1C12 |
72.25000 |
|
|
BC |
|
MBC1C12H |
71.90685 |
|
|
Sext |
|
MSA1C12 |
71.60500 |
|
|
|
Ion Pump |
VIP1C12 |
71.41180 |
1CB9 |
|
Dipole (3m) |
|
MBA1C09 |
69.50000 |
1C13 |
|
Quad |
|
MQA1C13 |
67.05000 |
|
|
BC |
|
MBC1C13V |
66.70685 |
|
|
Sext |
|
MSA1C13 |
66.40500 |
1CB10 |
|
Dipole (3m) |
|
MBA1C10 |
64.30000 |
1C14 |
BPM |
|
|
IPM1C14 |
62.22465 |
|
|
Quad |
|
MQA1C14 |
61.85000 |
|
|
BC |
|
MBC1C14H |
61.50685 |
|
|
Sext |
|
MSA1C14 |
61.20500 |
|
|
|
Ion Pump |
VIP1C14 |
61.01180 |
1CB11 |
|
Dipole (3m) |
|
MBA1C11 |
59.10000 |
1C15 |
|
|
Valve |
VBV1C15 |
|
|
|
|
Rough Pump |
VRV1C15 |
|
|
|
Quad |
|
MQA1C15 |
56.65000 |
|
|
BC |
|
MBC1C15V |
56.30685 |
|
|
Sect |
|
MSA1C15 |
56.00500 |
1CB12 |
|
Dipole (3m) |
|
MBA1C12 |
53.90000 |
|
Table 2.3:
Hall A Beamline Elements (continued)
Girder |
Diagnostic |
Optics |
Valves |
Element |
Distance (m) |
# |
Elements |
Elements |
& Pumps |
# |
from target |
1C16 |
|
|
Ion Pump |
VIP1C16 |
|
|
|
|
Convectron |
VTC1C16 |
|
|
BPM |
|
|
IPM1C16 |
51.82465 |
|
|
Quad |
|
MQA1C16 |
51.45000 |
|
|
BC |
|
MBC1C16H |
51.10685 |
|
|
|
Valve |
VBV1C16 |
|
SHIELD WALL(entrance surface) |
|
50.70700 |
From Shield Wall to Target and Dump |
|
|
SHIELD WALL (exit surface) |
|
49.651 |
1C17 |
TV Viewer |
|
|
ITV1C17 |
49.411 |
|
|
Quad |
|
MQA1C17 |
49.100 |
1C18 |
BPM |
|
|
IPM1C18 |
48.650 |
|
|
Quad |
|
MQA1C18 |
48.300 |
|
|
BC |
|
MBC1C18H |
47.957 |
|
|
BC |
|
MBC1C18V |
47.761 |
French |
Scanner |
|
|
IHA1C18A |
47.381 |
Bench |
Scanner |
|
|
IHA1C18B |
43.673 |
1C19 |
|
Quad |
|
MQA1C19 |
43.000 |
1C20 |
BPM |
|
|
IPM1C120 |
42.550 |
|
|
Quad |
|
MQA1C20 |
42.200 |
|
|
BC |
|
MBC1C20H |
41.857 |
|
|
BC |
|
MBC1C20V |
41.661 |
|
|
|
Ion Pump |
VIP1C20 |
41.450 |
COMPTON |
Polarimeter |
|
|
|
41.000 |
Region |
|
|
|
|
25.500 |
|
|
|
Ion Pump |
VIP1C20A |
34.500 |
|
|
|
Ion Pump |
VIP1C20B |
29.500 |
|
Current |
|
|
IBC1H00 |
|
|
|
|
|
IUN1H00 |
24.500 |
|
|
|
|
IBC1H00A |
|
Fast Raster |
|
|
|
MRA1H00H |
23.000 |
|
|
|
|
MRA1H00H |
|
|
|
|
Valve |
VBV1H00 |
22.053 |
eP Energy Target |
|
|
|
VTP1H00A |
21.650 |
|
|
|
Ion Pump |
VIP1H00A |
20.000 |
1H01 |
|
|
Valve |
VBV1H01 |
19.020 |
|
TV View |
|
|
ITV1H01 |
18.938 |
|
BPM |
|
|
IPM1H01 |
18.650 |
|
|
Quad |
|
MQA1H01 |
18.300 |
|
|
BC |
|
MBC1H01H |
17.957 |
|
|
BC |
|
MBC1H01V |
17.761 |
|
Table 2.4:
Hall A Beamline Elements (continued)
Moller target |
|
|
|
|
17.5000 |
1H02 |
|
Quad |
|
MQM1H02 |
16.500 |
|
|
|
|
VRV1H02A |
|
|
|
|
|
VTC1H02A |
|
1H03 |
|
Quad |
|
MQO1H03 |
15.415 |
1H03 |
|
Quad |
|
MQO1H03A |
14.758 |
Moller |
|
Dipole |
|
MMA1H01 |
13.272 |
|
|
|
Ion Pump |
VIP1H03A |
11.955 |
Bench |
|
BD |
|
MBD1H03H |
8.132 |
|
BLM |
|
|
IBC1H03A |
7.906 |
|
|
|
Valve |
VBV1H03A |
7.786 |
|
BPM |
|
|
IPM1H03A |
7.524 |
|
Scanner |
|
|
IHA1H03A |
7.353 |
|
|
|
Ion Pump |
VIP1H03B |
4.486 |
|
|
|
|
VTC1H03A |
|
|
BPM |
|
|
IPM1H03B |
1.286 |
|
Scanner |
|
|
IHA1H03B |
1.122 |
|
|
|
Valve |
VBV1H03B |
0.953 |
|
|
|
Radiator |
ERR1H |
0.726 |
TARGET TV Viewer |
ITV1H03A |
0.000 |
|
|
|
|
|
|
DUMP Face |
|
|
|
|
-50.000 |
|
|
|
|
|
|
|
All distances are from the center of each element to the target (in
meters).
Table 2.5:
Line A Optics and Beam Requirements at Target
Mode |
Spot Size |
Dispersion |
Position |
Size |
|
4* |
|
Stability |
Stability |
Achromat |
140m |
0 |
50m |
50m |
Dispersive |
|
4m to 12m |
50m |
50m |
Defocussed |
0 to 3mm |
0 |
10% |
10% |
|
Table 2.6:
Line A Optics and
Beam Requirements at Other Locations.
Mode |
Spot Size |
Dispersion |
Position |
Size |
|
4* |
|
Stability |
Stability |
Energy-eP(d) |
100m |
0 |
50m |
50m |
Moller Pol. (d) |
250m |
0 |
50m |
50m |
Compton Pol. |
80m |
0 |
50m |
50m |
*Energy-arc(d) |
|
15m |
50m |
50m |
Notes:
- *
- Build dispersion in arc section with all magnetic elements except
dipoles turned off.
- (d)
- Destructive measurements.
|
Next: Beam Position Monitors
Up: Beamline
Previous: Machine/Beamline protection system
  Contents
Joe Mitchell
2000-02-29