The vacuum in the target chamber is maintained by an Alcatel ( 880 l/s)
turbomolecular vacuum pump. The pump is connected to a 6 port in the
stainless steel ring between 130
. The vacuum pump is
fastened to a horizontal pipe connected to the chamber. The vacuum pressure in
the chamber is about
mm. An additional Alcatel pump connected
to an 8
port should be added to obtain lower vacuum. Both
pumps may be isolated
from the target chamber using gate valves which are remotely operated
from the vacuum control rack and interlocked to the FSD system.
A 2 all metal gate valve is located between the entrance flange to the
chamber and the beam profile monitor.
An additional gate valve is located 2 m downstream of the
target chamber to isolate the chamber from the exit beam pipe.