Beam Parameters
Energy |
1–11 GeV
|
Spread |
(1–5)E-4 (energy dependent, see MCC link above)
|
Current |
1–120 µA
|
Emittance |
2E-9 mrad
|
Spot Size |
300 µm
|
Beam Diagnostic Elements
Beam Position Monitors |
Transmission Line BPM (M15) with SE electronics. Resolution ≈ 20 µm at I ≈ 10 uA
|
Beam Current Monitors |
1 Unser (PCT) monitor with absolute accuracy of ±300 nA. Two RF cavity monitors tuned to 1.497 GHz with linearity of <0.5%
|
SuperHarps |
Destructive wire scanner; good for emittance measurements.
|
Beam Polarimeters
Moller Polarimeter |
Uses Moller scattering of the electron beam off electrons in a thin magnetized iron target. Moller polarimeters are mostly useful for low to mediem energies and low beam intensity.
|
Compton Polarimeter |
Uses Compton scattering (e-ɣ), where the electron beam is sent through a magnetic chicane and scattered from a photon beam. Compton polarimeters are mostly useful for medium to high energies and high beam intensity.
|