Trigger Setup for Hall A Spectrometers (E97111)


                               R. Michaels
                               update Oct 2, 2000

  I. Overview

  Here are a few notes about the trigger setup for
  the Hall A spectometers.  The main, so-called S-Ray
  trigger (T1 on R-arm and T3 on L-arm) is formed
  from a coincidence between two scintilator planes, S1
  and S2.  In each paddle of each plane, one first requires
  that the left and right PMTs fired, then these coincidences
  are fed into an MLU which is programmed to determine
  if the paddles that fired belong to an allowed set.
  Basically, this allowed set corresponds to tracks
  which come at a 45 degree angle to the lab floor,
  with some angular tolerance (+/- 1 paddle on each
  of S1,S2), and allowing any additional hits to 
  accompany.  Details of MLU programming are below.

  There are 5 trigger types:
        T1 = Right arm S-Ray
        T2 = Right arm "junk" (exclusive of T1)
        T3 = Left arm S-Ray
        T4 = Left arm "junk" (exclusive of T3)
        T5 = Coincidence between T1 and T3

  The "junk" triggers allow 1 detector to be missing: 1 out
  of [S1,S2,Cerenkov] on E-arm, 1 out of [S1,S2] on H-arm.
  For e97111, the R-arm is H-arm and the L-arm is E-arm.
  T2,T4 allow to measure efficiency, but they are mostly junk 
  and have to be cleaned up with tracking.  
  
  There should be no, or extremely few, "missing gate"
  events, which had bothered us in the ancient past and 
  had made the frontend buffering unusable.  Nevertheless
  it is VERY IMPORTANT to verify good synchronization of 
  the DAQ, by checking correlations between various quantities, 
  like : (i) VDC track versus scintillator hit, (ii) ADC channel 
  versus TDC channel for scintillators, (iii) Target Y from 
  R-arm versus Y from L-arm, (iv) Scattering angles
  of R-arm versus L-arm.

  There is a possible mislabeling of CODA event types
  due to timing overlap at trigger supervisor.  There was
  nothing I could do to avoid this ambiguity because of
  tight timing of the delay spools.  The consequence is
  the eventy type 3 could be 5, etc.  But the trigger 
  pattern is latched each event in a TDC, for e97111
  this appears in roc1, slot3, channels 1-12 for triggers
  after prescaling and channels 17-29 for triggers before
  prescaling.  The former 'event type 14' is now programmed
  to be event 5 to make old software as happy as possible.

  You may also see funny bumps in the ``TC'' spectra 
  (TC is the ESPACE name for the coincidence time measured 
  in a TDC 1875 with 0.1 nsec resolution on the R-arm.)
  Some of these bumps come from inefficiency and 
  serve as a measure of the trigger inefficiency.
  Some come from pileup effects or ``missing gates''.
  I have some notes in my office about this.  It is
  highly recommended to understand it.  However, if
  you take T5 and demand a track, the strange
  bumps disappear. 


  part II.  Instructions to Download Trigger

   On an HP-UX computer like adaqh2, from the ``adaq''
   account, type ``trigsetup''.
   Answer the obvious questions.  There are currently ten
   setup files to choose from.  To select the one you
   want, you have to answer the hadron arm momentum
   at the prompt.  This assumes the hadron is a PROTON
   and the momentum is in GEV.  The script will calculate
   the delay and tell you which setup file it plans to
   use, giving you a chance to reply if it is ok.

   If you put in a wrong momentum (i.e. outside the
   valid range 0.36 to 4.0 GeV), you get a second
   chance -- you can choose from the ten setup files
   which are listed by the script. You have to answer 
   which one you want, then XTrigMang is started and 
   you have to push the button 'download all'

   Downloading takes about 2-3 minutes.  At the 
   end, the XTrigMang window becomes alive, and
   you can press the ``quit'' button.
   
   If you get errors about "unable to connect", etc, 
   you might have to reboot the VME crate(s) which
   serve CAMAC.  This can be done remotely.  In some
   cases, you may need to reboot CAMAC, which cannot
   be done remotely.  When electrical power is lost
   in Hall A, it is necessary to reload the trigger.


  A typical session with trigsetup:
 
adaqh2> trigsetup
trigsetup will provide to XTrigMang a trigger settings file
corresponding to the hadron momentum which you enter below
The momentum must be for a PROTON, and must be in GEV.
(If you enter in invalid momentum, you will have a chance
 to choose from the list of settings files.)
 
Enter proton momentum in GeV (between 0.36 and 4.00)
.88
 
Trigger file to download = proton_875-1170.settings
 
(Reminder: the file names contain the hadron name and
range of the hadron momentum where the settings will work)
 
Is this what you want ?  (answer 'y' for yes)
 
y
 
Starting XTrigMang....
Press the button :  download all

It is finished when the screen from which you launched 
XTrigMang tells you. 

--------------- end of section II ------------------------------

  Part III.  MLU files 

  This long, boring section explains the MLU files
  and can be safely ignored by most users.  

 Concepts:

   The 1st MLU is programmed the same for
 each spectrometer.  There are 12 inputs
 from 12 scint.  Also, on input 15 is the
 pulser which is an "x" (don't care).
 The Strobe comes from the OR of S2-OR
 or S1-OR.  The S2-OR signal comes ~15 nsec
 before the S1-OR so it normally defines the
 timing.
  
 The outputs of MLU1 are
   bit 1 and 4 (4 is a copy)  "2-2" S-Ray
   bit 2 and 5                S1-OR
   bit 3 and 6                S2-OR
   bit 7               Strobe (from S1 or S2)
 The mlu file is mlu1_scint.data
 The version which requires pulser on 15,
 and doesn't care about the other 12 inputs
 is mlu1_pulse.data.

 The Strobe output goes to the re-timing
 circuit.  Bits 1,2,3 outputs go to the 
 2nd MLU inputs 1,2,3.  On the electron
 arm, the Cerenkov goes into input 4 of MLU2.
 On the hadron arm nothing goes into bit 4.

 For both spectrometers, if S-Ray is present 
 it puts out bit 1 = trigger 1 (called trigger
 3 for L-arm).  If S-Ray is absent, then 
 trigger 2 (resp 4 on L-arm) may be formed 
 as follows.  On the which arm has electrons, 
 2 out of 3 hits are required from S1-OR, S2-OR,
 and Cerenkov.  This is a majority logic scheme.
 On the hadron arm, the junk trigger is the 
 "OR" of S1,S2.

 Triggers 1 and 2 are exclusive.  Trigger 2 
 will not go to the coincidence circuit.  
 Similarly for triggers 3 and 4.

 Typically the T0 (timing offsets) of the triggers
 can be quite different, especially comparing the
 S-ray to the "junk" triggers.

 Technical details of MLU programming follow.

 I. Files for 1st MLU:  mlu1_scint.data
  (version for pulser tests: mlu1_pulse.data)
  This is used by both R-arm and L-arm.

  The 2_2 S-Ray trigger is generated
  with 
     XYmlu -f mlu_2_2_andbgr_generate.dat
  and compressed with
       mlu_compress
  The result is renamed mlu_2_2.data

  Note: S0 does not go into MLU1.
  The L,R PMTs go into inputs 4,5 of MLU2.  

  The s1-or is generated with 
       XYmlu -f s1or_generate.dat
  and s2-or with s2or_generate.dat;
  both are compressed with mlu_compress.
  The results are renamed mlu_s1or.data
  and mlu_s2or.data

  The 3 files are merged for bit-wise
  or of the outputs.  Two files can
  be merged at a time using mlu_bitmerge.

   mlu_bitmerge mlu_2_2.dat mlu_s1or.data

  Call the result of this mlu_temp.dat;
  then
   mlu_bitmerge mlu_temp.dat mlu_s2or.data
  
  The result is the MLU file for MLU1. 
  Renamed:

   <<<   mlu1_scint.data  >>>

  In the case of mlu1_pulse.data, the above
  combinations are allowed, in addition the
  pulser on input 15 is allowed to overlap
  with the any combination of 12 inputs (else
  the probability to overlap would be too small).
  We do:
     XYmlu -f mlu_2_2_pulse_generate.dat
  Let result be mlu.data, then concatenate:
    cat mlu.data mlu1_scint.data > mlu1_pulse.data


  II. File for 2nd MLU on Electron arm
  (For e97111, the Left arm is the Electron)
      mlu2_electron.data

   Generate with
       XYmlu -f mlu2_electron_generate.dat
   compress this, call it temp1.dat
  
   Get the luminosity monitor file
       XYmlu -f mlu2_lum_generate.dat
   compress this, call it temp2.dat

   Merge the above two files
       mlu_bitmerge temp1.dat temp2.dat

   Result:

      <<<  mlu2_electron.data >>>

      
  III. File for 2nd MLU on hadron arm
      is mlu2_hadron.data.  The version used at
      present does not use S0, instead it does
      the "OR" of S1,S2 as prior to Nov 20, 1999.

   Generate with
       XYmlu -f mlu2_hadron_generate.dat
   compress this, call it temp1.dat

   Get the luminosity monitor file
       XYmlu -f mlu2_lum_generate.dat
   compress this, call it temp2.dat

   Merge the above two files
       mlu_bitmerge temp1.dat temp2.dat

   Result:

      <<<  mlu2_hadron.data >>>


  Appendix -- MLU utilities routines on adaq HP machines

  Type the name of the utility without arguments and
  it will introduce itself, and explain its usage.


    XYmlu -- takes a pattern like 10xx01 and
    generates all mlu entries.  1=bit must be true;
    0=bit must be false; x=bit may be 0 or 1.
    There is a Y option, but it is little used
    and not too important.

    btst -- Examines a pattern of bits 

    mlu_compress -- Takes an mlu file and
    examines all pairs of line-entries.  If the
    two line entries are identical, one is kept,
    the other discarded (this isn't really necessary
    but speeds up the download).  Also the bit-wise
    OR of 2nd components is taken if first components
    are identical.

    mlu_compare -- Compares two mlu files
    to see what is different.  If no optional
    argument is given, any difference in the 
    file are noted.  If an argument is given
    (any number), only the first entry of each
    pair are compared.

    mlu_bitmerge -- Merges two mlu files.  For
    each pair of line entries "X1 Y1" from file 1
    and "X2 Y2" from file2, if X1=X2, then the
    two entries are merged to form bit-wise OR
    of Y1,Y2, i.e. we get "X3 Y3" where Y3 = Y1 | Y2.



This page maintained by rom@jlab.org