Robert Michaels, rom@jlab.org, Jefferson
Lab Hall A, updated Aug 8, 2007
Here is a checklist for experts only to switch the DAQ from coincindence mode (TWOARM) to 2-DAQ mode. The former is defined as having one trigger supervisor (TS) on R-HRS which controls all the crates; the latter has two independent TS, L-HRS and R-HRS, and hence 2 DAQ systems for singles mode.
STEP | PROCEDURE |
1 | L-HRS: Switch TS RS485 cable at Fastbus ROC4 |
2 | L-HRS: ts_scaler.crl RLSWITCH = LOCAL vs RARM. |
3 | R-HRS: Modify boot scripts (adev vs a-onl), reboot |
4 | L-HRS: Move origin of L1A |
5 | L-HRS: Move origin of scaler gates |
6 | a-onl: Modify runend.tcl, halla_scaler_process.tcl and last_scaler |
7 | atrig: Default trigsetup to coinc or 2daq |
8 | datamon deadtime (scdtime.c switch) |
9 | L-arm: runTypes pedrun vs pedrunL |
10 | auto BTA (1-arm vs 2-arm). |
11 | Download the trigger & answer obvious questions |