Moller Measurements for E02-006 PREX, March - June 2010
The Moller results are presented in a table below and on the plot.ps or
plot.png
For PREX new 'BRUTE FORCE' Moller target was built and installed. It uses a superconducting magnet for the Moller target magnetization
saturation. Two alignments of the magnet magnetic field were done by alignment group (March 30 and April 16).
Three different Moller quads settings were used for PREX running period. Different combinations of the magnet alignment and quads
settings require using different analyzing power value for the Moller data analyzes.
The most of Moller measurement were done at 3T magnetic field. As it was shown later, the Moller target was not fully saturated
at this magnetic field. Due to that, correction on the target saturation was done for 3T measurements.
As a result of combination of low beam energy, different quads setting and magnet misalignment, we had different Levchuk-effect
( ref1 and
ref2 ) contribution for different magnetic fields.
Corrections of the Moller results on all of the effects were done.
More information about the corrections and systematic error is given
here .
Beam polarization measurements with the Moller polarimeter were done at the beam current 1.5-3.0uA. Beam current for PREX data
taken was about 50uA. Possible systematic error caused by the beam current difference was studied in the
ref . Summary of the test with three different
methods of the beam current adjustment is presented on the plot . From the plot a contribution
to the systematic error due to the beam current difference for PREX running and Moller measurements is +/-0.3%. The total
systematic error (including the beam current correction) is 1.12%
# date raw polar. Cor. polar* Stat.err. Syst.err. Wien filter --------------------------------------------------------------------- 1 04.03.2010 -85.31 -84.85 +/- 0.10 +/- 1.12% -59.0 2 04.05.2010 -88.71 -87.24 +/- 0.20 +/- 1.12% -52.0 3 04.17.2010 -88.53 -89.08 +/- 0.14 +/- 1.12% -52.0 4 04.22.2010 +90.58 +90.88 +/- 0.14 +/- 1.12% -52.0 5 04.28.2010 -89.30 -89.60 +/- 0.12 +/- 1.12% -52.0 6 05.05.2010 -91.00 -90.39 +/- 0.15 +/- 1.12% -52.0 7 05.08.2010 +90.89 +90.29 +/- 0.15 +/- 1.12% -52.0 8 05.15.2010 -92.49 -89.94 +/- 0.16 +/- 1.12% -52.0 9 06.07.2010 -91.37 -90.49 +/- 0.11 +/- 1.12% -52.0* Levchuk-effect and target saturation corrections
The details of the measurements can be found here .