Moller Measurements for E06-014 d2n, Feb - Mar 2009
The Moller results are presented in a table below and on a plot .
# date day Moller Moller with HALLA:p Syst.err. WienF --------------------------------------------------------------------- 1 02.07 2 -75.39 +/- 0.11 -79.40 +/- 0.11 +/- 2.0% 30.0 2 02.09 4 -71.62 +/- 0.13 -71.70 +/- 0.13 +/- 2.0% 30.0 3 02.11 6 +73.38 +/- 0.15 +74.72 +/- 0.15 +/- 2.0% 23.0 4 02.19 14 -74.05 +/- 0.11 -74.49 +/- 0.11 +/- 2.0% 23.0 5 03.03 26 -80.32 +/- 0.12 -79.65 +/- 0.12 +/- 2.0% 30.0 6 03.06 29 +65.29 +/- 0.11 +63.93 +/- 0.11 +/- 2.0% -18.0 7 03.12 35 -60.79 +/- 0.13 -60.79 +/- 0.13 +/- 1.7% 21.2* day - day of experiment running
Measurement 2
1 pass.
Measurement 3
Mini spin dance. Wien angle 23deg was choosen.
Measurements 6 and 7
4 passes.
Measurement 7:
The beam energy was stable (fluctuation was less than +/-0.1MeV).
The beam energy correction for the Moller results is not needed. Systematic error is 1.7%
The details of the measurements can be found here .