The beam energy is 1.0457 (arc, ep). Injector angle is 10.2o, the 1/2 wave plate was OUT.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10426-10427 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10420-10425 | 23.0 | -63.2+/-0.5 | 18.3 | -61.3+/-0.5 | 0.4 | |
10428-10433 | 163.5 | -63.3+/-0.6 | 160.1 | -64.5+/-0.6 | 1.0 | |
Average | - | -63.2+/-0.4 | - | -62.9+/-0.4 | - | Av: -63.1+/-0.4 Dead time not included |
PROBLEM: the helicity delay is different from the October running. We had to put delay=10 instead of
9 running the asyms.kumac. This provides a high polarization, other values give
much lower polarizations. Or, one had to use the helicity from the ADC events.
The problem was that the helicity signal change came a bit
later than the end of pulse. It was fixed on Jan,9 by inserting a 150ns delay in trigger 2.
The full information is given
here .
The plot is given
here .
The final results:
Pz=-63.1 +/- 0.4(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, 10.2o Wien angle)
(dead time correction NOT DONE)
The spin angle is large: cos(angle)=0.8 accordingly to our estimate, therefore the full polarization is about -80%.
The beam energy is 4.0157 (arc, ep). Injector angle is -25.7o, the 1/2 wave plate was OUT.
The collimator width was 2cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10448-10449 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10442-10447 | 23.0 | -74.0+/-0.3 | 19.4 | -72.2+/-0.3 | 4.0 | |
10453-10458 | 163.5 | -66.4+/-0.3 | 158.8 | -68.3+/-0.3 | 2.0 | Att=185 slit=21.5 |
Average | - | -70.2+/-0.2 | - | -70.2+/-0.2 | - | Av: -70.2+/-0.2 Dead time not included |
10460-10463 | 163.5 | -66.8+/-0.3 | - | - | 0.1 | Att=50 slit retracted |
During the measurement at Att=185,slit=21.5 something was changed in G0 setting (run 10451) and the current went up to 1.0µA. The slit was retuned to 19. We checked the influence of the attenuator: at the slit rectracted the beam current went from 0.3 to 5.0 µA when the attenuator was changed from 50 to 185.
The full information is given
here .
The plot is given
here .
The final results:
Pz=-70.2 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -25.7o Wien angle)
(dead time correction NOT DONE)
The spin angle is large: cos(angle)=0.94 accordingly to our estimate, therefore the full polarization is about -74%.
The beam energy is 4.0157 (arc, ep). Injector angle is -25.7o, the 1/2 wave plate was IN.
The collimator width was 3cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10474-10475 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10468-10473 | 23.0 | +76.2+/-0.2 | 19.2 | +74.3+/-0.2 | 5.0 | |
10475-10481 | 163.0 | +68.8+/-0.2 | 158.7 | +70.7+/-0.2 | 1.2 | |
Average | - | +72.5+/-0.2 | - | +72.5+/-0.2 | - | Av: +72.5+/-0.2 Dead time not included |
10482-10485 | 163.0 | -69.3+/-0.2 | - | - | 11. | ApL removed from coincidence |
10486 | - | - | - | - | - | No target, 10µA low threshold |
The beam current was unstable, presumably because of G0.
The full information is given
here .
The plot is given
here .
The final results:
Pz=+72.5 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate IN, -25.7o Wien angle)
(dead time correction NOT DONE)
The beam energy is 5.0057 (arc, ep). Injector angle is -16.2o, the 1/2 wave plate was IN.
The collimator width was 3cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10497-10498 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10491-10496 | 23.0 | +80.8+/-0.2 | 19.0 | +78.7+/-0.2 | 0.5 | |
10499-10504 | 163.0 | +76.4+/-0.2 | 159.1 | +78.2+/-0.2 | 0.4 | |
Average | - | +78.6+/-0.2 | - | +78.5+/-0.2 | - | Av: +78.6+/-0.2 Dead time not included |
10505-10510 | 163.0 | +76.3+/-0.2 | - | - | 0.7 | Collimator -1cm |
The full information is given
here .
The plot is given
here .
The final results:
Pz=+78.6 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate IN, -16.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 5.0057 (arc, ep). Injector angle is -16.2o, the 1/2 wave plate was OUT.
The collimator width was 3cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10521-10522 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster OFF |
10513-10520 | 23.0 | -79.9+/-0.2 | 19.8 | -78.2+/-0.2 | 4.0 | |
10523-10530 | 163.5 | -75.4+/-0.2 | 160.9 | -76.3+/-0.2 | 1.1 | |
Average | - | -77.6+/-0.2 | - | -77.2+/-0.2 | - | Av: -77.4+/-0.2 Dead time not included |
10531-10534 | 91.5 | - | - | - | - | High statistics at 90 deg |
The full information is given
here .
The plot is given
here .
The final results:
Pz=-77.4 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -16.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 5.0057 (arc, ep). Injector angle is -16.2o, the 1/2 wave plate was OUT.
The collimator width was 3cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10543-10544 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10537-10542 | 23.0 | -81.1+/-0.2 | 19.0 | -79.0+/-0.2 | 0.5 | |
10545-10550 | 163.0 | -77.3+/-0.2 | 159.5 | -78.9+/-0.2 | 1.0 | |
Average | - | -79.2+/-0.2 | - | -79.0+/-0.2 | - | Av: -79.1+/-0.2 Dead time not included |
The full information is given
here .
The plot is given
here .
The final results:
Pz=-79.1 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -16.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 3.033 (arc, ep). Injector angle is +16.2o, the 1/2 wave plate was IN.
The collimator width was 3cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10571-10572 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10565-10570 | 23.0 | -80.5+/-0.2 | 19.0 | -78.4+/-0.2 | 0.6 | |
10573-10578 | 163.0 | -76.4+/-0.2 | 159.0 | -78.2+/-0.2 | 1.0 | |
Average | - | -78.5+/-0.2 | - | -78.3+/-0.2 | - | Av: -78.4+/-0.2 Dead time not included |
The full information is given
here .
The plot is given
here .
The final results:
Pz=-78.4 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, +16.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 5.005 (arc, ep). Injector angle is -10.0o, the 1/2 wave plate was OUT.
The collimator width was 3cm.
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10594-10595 | 90.0 | - | 0.30uA | - | - | thr=240mV, raster ON |
10588-10593 | 23.0 | -86.0+/-0.2 | 19.3 | -83.9+/-0.2 | 2.5 | |
10596-10601 | 163.0 | -84.2+/-0.2 | 160.0 | -85.6+/-0.2 | 1.0 | |
Average | - | -85.1+/-0.2 | - | -84.8+/-0.2 | - | Av: -84.9+/-0.2 Dead time not included |
10603-10605 | 163.0 | - | 160.0 | - | - | Roman's tests of new CAMAC software |
10606 | out | - | 10uA | - | - | No target. BG check low thresh. |
10607 | out | - | 10uA | - | - | No target. BG check high thresh. |
The full information is given
here .
The plot is given
here .
The final results:
Pz=-84.9 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -10.0o Wien angle)
(dead time correction NOT DONE)
The beam energy is 1.148 (arc, ep). Injector angle is 44.8o(changed to 30o), the 1/2 wave plate was OUT.
The collimator width was 3cm (increased to max after run 10626).
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10644-10645 | 90.0 | - | 0.15uA | - | - | thr=240mV, raster OFF |
10636-10637 | 23.0 | 70.5+/-0.5 | 18.5 | 68.4+/-0.5 | 0.0 | Wien 44.8o |
10646-10647 | 163.0 | 60.9+/-0.5 | 161.3 | 61.5+/-0.5 | 0.0 | |
Average | - | 65.7+/-0.3 | - | 65.0+/-0.3 | - | Av: 65.3+/-0.3 Dead time not included |
10641-10642 | 23.0 | -30.0+/-5.0 | - | - | - | Hall A beam=0, rate 1% |
10641-10642 | 23.0 | -30.0+/-5.0 | - | - | - | Hall A beam=0 |
10652-10653 | 90.0 | - | 0.15uA | - | - | Wien 30.2o |
10654-10655 | 23.0 | 76.9+/-0.6 | 18.6 | 74.7+/-0.6 | 0.0 | |
10649-10650 | 163.0 | 70.2+/-0.5 | 161.5 | 73.1+/-0.5 | 0.0 | |
Average | - | 73.5+/-0.4 | - | 72.7+/-0.4 | - | Av: 73.1+/-0.3 Dead time not included |
The full information is given
here .
The plot is given
for Wien angle of 44.8 and
for Wien angle of 30.2 degrees .
The final result at Wien=30.2o with a correction of 1.5% relative for the dilution (from Hall B) is:
Pz=74.1 +/- 0.4(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, 30.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 1.5422 (acc). Injector angle is -25.0o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm).
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10669-10670 | 90.0 | - | 0.20uA | - | - | thr=240mV, raster ON |
10665-10668 | 23.0 | 79.5+/-0.2 | 18.7 | 77.3+/-0.2 | 0.8 | |
10671-10676 | 163.0 | 75.2+/-0.2 | 160.2 | 76.5+/-0.2 | 0.8 | |
Average | - | 77.4+/-0.2 | - | 76.9+/-0.2 | - | Av: 77.1+/-0.2 Dead time not included |
10661-10662 | 23.0 | 78.1+/-0.3 | - | - | 0.0 | 0.35uA |
10663-10664 | 23.0 | -45.0+/-3.0 | - | - | 0.0 | 0.uA - leak through for 0.3uA slit: 1% coinc |
10683 | 163.0 | -40.0+/-8.0 | - | - | 0.0 | 0.uA - leak through for 0.2uA slit: 1% coinc |
The full information is given
here .
The plot is given
here .
The final result with a correction of 1.3% relative for the dilution (from Hall B) is:
Pz=78.1 +/- 0.2(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -25.0o Wien angle)
(dead time correction NOT DONE)
The beam energy is 1.148 (acc). Injector angle is 30.5o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm).
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10728-10729 | 90.0 | - | 0.15uA | - | - | thr=250mV, raster ON, A,C OFF |
10722-10727 | 23.0 | 77.2+/-0.4 | 18.8 | 75.1+/-0.4 | 0.6 | |
10730-10735 | 163.0 | 71.6+/-0.4 | 159.3 | 73.1+/-0.4 | 0.6 | |
Average | - | 74.4+/-0.3 | - | 74.1+/-0.3 | - | Av: 74.2+/-0.3 Dead time not included |
10737-10738 | 163.0 | - | - | - | 0.0 | LED all, D.T.=2.5% |
10743-10744 | 163.0 | - | - | - | 0.0 | LED 2x6, D.T.=3.5% |
10745-10746 | 163.0 | - | - | - | 0.0 | LED 1x7, D.T.=4.0% |
10747-10748 | 163.0 | - | - | - | 0.0 | LED 1x7, D.T.=3.8% accid*LED |
10749,10751 | 163.0 | - | - | - | 0.0 | LED 3x5, D.T.=3.0% accid*LED |
10753-10754 | 163.0 | -34.0+/-5.0 | - | - | - | Hall A laser OFF, Hall C ON 20uA: 1.2% leakthrough |
10758,10761 | 163.0 | - | - | - | 0.0 | ApL HV scan: 1900V 100%, 1850V 98%, 1800 90%, 1750 50% |
10762 | 163.0 | 67.8+/-1.0 | - | - | 0.0 | Collim 8mm pos (all range = 40mm) |
10763 | 163.0 | 69.6+/-1.3 | - | - | 0.0 | Collim 16mm pos |
10764 | 163.0 | 69.5+/-1.7 | - | - | 0.0 | Collim 24mm pos |
10765-10766 | 163.0 | 69.1+/-0.6 | - | - | - | Normal setting, thresh = 250mV |
10767-10768 | 163.0 | 69.4+/-0.6 | - | - | - | thresh = 260mV |
10769-70,79-80 | 163.0 | 70.7+/-0.4 | - | - | - | thresh = 300mV |
10771-72,81-82 | 163.0 | 70.4+/-0.4 | - | - | - | thresh = 350mV |
10773-74,83-84 | 163.0 | 71.6+/-0.4 | - | - | - | thresh = 400mV |
10775-10778 | 163.0 | 70.2+/-0.4 | - | - | - | thresh = 200mV |
10785-10786 | 163.0 | 69.5+/-0.6 | - | - | - | thresh = 250mV |
10787-10790 | 163.0 | 70.2+/-0.6 | 0.09uA | - | - | (250mV) Current scan, Hall C =20uA |
10791-10792 | 163.0 | - | 0.09uA | - | - | LED: D.T.=1.8%, Hall C =40uA |
10793 | 163.0 | -42.0+/-8.0 | 0.uA | - | - | Leakthrough 2% |
10794-10797 | 163.0 | 67.5+/-0.3 | 0.53uA | - | - | (250mV) Current scan, Hall C =40uA |
10798-10799 | 163.0 | - | 0.53uA | - | - | LED: D.T.=10.2%, Hall C =40uA |
10801 | 163.0 | 70.7+/-0.6 | 0.uA | - | - | Leakthrough: 2% |
The full information is given
here .
The plot is given
here .
The final result (no leakthrough correction needed)
Pz=74.2 +/- 0.3(stat) +/- 3.0(syst-prelim) (1/2 wave plate OUT, 30.5o Wien angle)
(dead time correction NOT DONE)
The beam energy is 2.235 (acc). Injector angle is 30.5o, the 1/2 wave plate was IN.
The collimator width was at max (4cm).
runs | Dial angle | Calculated angle | chi2 | comments | ||
---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | |||
10822-10823 | 90.0 | - | 0.35uA | - | - | thr=250mV, raster OFF, C ON |
10836-10839 | 23.0 | 62.5+/-0.2 | 18.3 | 60.6+/-0.2 | 10.0 | |
10824-10827 | 163.0 | 58.4+/-0.2 | 160.6 | 60.2+/-0.2 | 1.5 | |
Average | - | 60.4+/-0.2 | - | 59.9+/-0.2 | - | Av: 60.2+/-0.2 Dead time not included |
10834-10835 | 23.0 | -32.9+/-1.0 | - | - | - | A laser off, normal slit |
10832-10833 | 23.0 | -32.3+/-0.2 | - | - | - | A laser off, open slit |
10828-10829 | 163.0 | -26.3+/-1.2 | - | - | - | A laser off, normal slit |
10830-10831 | 163.0 | -30.2+/-0.2 | - | - | - | A laser off, open slit |
10840 | 23.0 | - | - | - | - | LED: D.T.= 3.7%, Hall C =85uA |
A huge leakage from Hall C, working at 85µA has been observed.
With the attenuator at 500 and the slit at 17.95 the leakage was about C/A=9.5%.
The Hall C polarization was -31.2+/-0.2%.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction A=Aobs+C/A*(Aobs-AC)
Pz=68.9 +/- 0.2(stat) +/- 2.0(dilution) +/- 3.0(syst-prelim) (1/2 wave plate IN, 30.5o Wien angle)
(dead time correction NOT DONE)
The beam energy is 2.235 (acc). Injector angle is 30.5o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster ON.
Purpose: studies of the leakage from Hall C
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
10843-10846 | 23.0 | 59.4+/-0.2 | - | - | 2.0 | 0.30 | 93 | 18.0 | P=59.4*1.122+31.6*0.122=70.5+/-0.2 |
10847-10850 | 23.0 | -32.9+/-0.6 | - | - | 3.0 | 0.00 | 93 | 18.0 | |
10851-10852 | 23.0 | -31.6+/-0.2 | - | - | 4.0 | 0.00 | 93 | 18.0 | |
10853-10856 | 23.0 | 75.6+/-0.2 | - | - | 2.0 | 0.35 | 0 | 18.0 | |
10860-10861 | 23.0 | 43.7+/-0.2 | - | - | 8.0 | 0.30 | 93 | 23.0 | P=43.7*1.355+31.6*0.355=70.3+/-0.2 |
10862-10863 | 23.0 | -31.6+/-0.5 | - | - | 5.0 | 0.00 | 93 | 23.0 |
The Hall A polarizations, corrected for the Hall C leakage, are the same (70.5% and 70.3%) for the 12% and 35% dilutions. However, the Hall A polarization, measured with Hall C off, was 75.6%, or 7.3% (relative) more!
The full information is given here .
The beam energy is 3.322 (acc). Injector angle is 30.2o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster ON.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
10875-10876 | 90.0 | - | - | - | - | 0.30 | 98 | 15.5 | |
10867-10868 | 23.0 | 73.2+/-0.4 | 19.3 | 71.4+/-0.4 | 1.0 | 0.30 | 98 | 15.5 | |
10869-10870 | 163.0 | 69.9+/-0.4 | 19.3 | 72.0+/-0.4 | 1.0 | 0.30 | 98 | 15.5 | |
Average | - | 71.5+/-0.3 | - | 71.7+/-0.3 | - | 0.30 | 98 | 15.5 | Av: 71.6+/-0.3 Dead time not included |
The Hall C leakage was 2.4% at this slit position (15.5).
The full information is given
here .
The plot is given
here .
The final result with the leakage correction P=71.6*1.024+30.0*0.024=74.0+/-0.3
Pz=74.0 +/- 0.3(stat) +/- 1.0(dilution) +/- 3.0(syst-prelim) (1/2 wave plate IN, 30.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 3.322 (acc). Injector angle is 42.0o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster ON.
runs | Dial angle | Calculated angle | chi2 | laser | comments | |||||
---|---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | laser A | A, µA | C, µC | A slit | |||
10878-10881 | 23.0 | 76.7+/-0.2 | - | - | 1.0 | on | 0.300 | 0 | 15.0 | phase A -26.44 |
10882-10883 | 23.0 | 76.5+/-0.2 | - | - | 0.0 | on | 0.300 | 0 | 16.2 | phase A -33.00 |
10884 | 23.0 | 65.4+/-0.3 | - | - | 0.0 | on | 0.530 | 98 | 16.2 | phase A -33.00 |
10885-10886 | 23.0 | 64.6+/-0.3 | - | - | 0.0 | on | 0.300 | 98 | 15.4 | the same |
10887-10888 | 23.0 | -29.9+/-1.2 | - | - | 0.0 | off | 0.026 | 98 | 15.4 | |
10889-10890 | 23.0 | -31.2+/-0.2 | - | - | 0.0 | off | 0.390 | 98 | -1.0 | |
10892-10893 | 23.0 | -30.3+/-1.1 | - | - | 0.0 | off | 0.039 | 98 | 16.2 | |
10894-10895 | 23.0 | 66.8+/-0.3 | - | - | 0.0 | on | 0.680 | 98 | 16.2 | |
10896-10897 | 23.0 | 71.2+/-0.3 | - | - | 1.0 | on | 0.640 | 40 | 16.2 | |
10898 | 23.0 | -28.6+/-2.4 | - | - | 0.0 | off | 0.022 | 40 | 16.2 | |
10899-10900 | 23.0 | 74.3+/-0.2 | - | - | 1.0 | on | 0.600 | 10 | 16.2 | |
10901 | 23.0 | -23.7+/-4.0 | - | - | 0.0 | off | 0.017 | 10 | 16.2 |
The full information is given here .
The beam energy is 2.1344 (acc). Injector angle is -72.2o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm), thr=250mV, raster ON.
Mott from the next day (Jul,18): 71.0+/-0.7(stat) (see ELOG) and 76+/-1.7% on July,10 (see ELOG)
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
10907-10908 | 90.0 | - | - | - | - | 0.25 | 35 | 12.8 | |
10911-10912 | 23.0 | 74.5+/-0.3 | 19.5 | 72.8+/-0.2 | 0.0 | 0.25 | 35 | 12.8 | |
10913-10916 | 163.0 | 70.3+/-0.2 | 160.4 | 71.4+/-0.2 | 5.0 | 0.25 | 35 | 12.8 | |
Average | - | 72.5+/-0.2 | - | 72.1+/-0.2 | - | - | - | - | Av: 72.3+/-0.2 Dead time not included |
10917-10918 | 163.0 | 32.5+/-2.5 | 160.4 | 33.0+/-2.5 | 99.0 | 0.00 | 35 | 12.8 | Hall C: 1.3% leak through |
10920-10923 | 163.0 | 72.8+/-0.2 | - | - | 3.0 | 0.25 | 0 | 12.8 | Hall C off |
The Hall C leakage was 1.3% at this slit position (12.8), 35µA.
The helicity is NON-delayed. There is a delay discrepancy in comparison with the dalayed data we had before. This is explained in the next measurement, at July,21.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction P=72.3*1.013+33.0*0.013=73.7+/-0.2
Pz=73.7 +/- 0.2(stat) +/- 0.5(dilution) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -72.0o Wien angle)
(dead time correction NOT DONE)
With the Hall C off the polarization at at 163 deg is 72.8+/-0.2%, about 1.4% higher than the result with the Hall C on, corrected for the leakage: 70.3*1.013+33*0.013=71.6%.
The beam energy is 2.1344 (acc). Injector angle is -72.2o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster ON.
Mott: 71.0+/-0.7(stat) (see ELOG)
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
10936-10937 | 90.0 | - | - | - | - | 0.30 | 60 | 13.26 | |
10932-10935 | 23.0 | -75.0+/-0.2 | 18.6 | -72.8+/-0.2 | 10.0 | 0.30 | 60 | 13.26 | |
10938-10941 | 163.0 | -69.5+/-0.2 | 158.9 | -71.2+/-0.2 | 2.0 | 0.30 | 60 | 13.26 | |
Average | - | -72.2+/-0.2 | - | -72.0+/-0.2 | - | 0.30 | 60 | 13.26 | Av: -72.1+/-0.2 Dead time not included |
10942-10945 | 163.0 | 40.0+/-1.3 | 158.9 | 41.0+/-1.3 | 99.0 | 0.00 | 60 | 13.26 | Hall C: 2.2% leak through |
10946 | 0.0 | - | - | - | - | 0.30 | 60 | 13.26 | no target |
10930 | 23.0 | -74.8+/-0.4 | - | - | - | 0.30 | 60 | 13.26 | Helicity delay 8 |
10931 | 23.0 | -73.5+/-0.4 | - | - | - | 0.30 | 60 | 13.26 | Helicity delay 4 |
The Hall C leakage was 2.2% at this slit position (13.26).
There is a difference in the helicity signal timing depending on the delay. With a delay the start of helicity coincides with the synchro-signal, without a delay there is a 25µs delay of the helicity (see this picture ). The asymmets.f program is using the helicity of the scaler event and is tuned for the delayed scheme. A shift of one period is permanently applied, since the scaler event is reading the helicity signal for the NEXT period. This is not needed to the non-delayed data, because of the 25µs delay. The recommendation is to use the ADC heliciy (heladc=1 parameter in the asyms.kumac). On July,22 the Clock*Helicity signal is added to the 1-st scaler, channel 10. It can be used for the ultimate helicity definition in the scaler event.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction P=-72.1*1.022-40.0*0.022=-74.6+/-0.2
Pz=-74.6 +/- 0.2(stat) +/- 0.5(dilution) +/- 3.0(syst-prelim) (1/2 wave plate IN, -72.0o Wien angle)
(dead time correction NOT DONE)
The beam energy is 4.210 (acc). Injector angle is -20.0o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm), thr=250mV, raster ON.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
10960-10961 | 90.0 | - | - | - | - | 0.30 | 88 | 14.28 | |
10956-10959 | 23.0 | -60.0+/-0.2 | 18.8 | -58.3+/-0.2 | 11.0 | 0.30 | 88 | 14.28 | |
10962-10965 | 163.0 | -60.5+/-0.2 | 159.4 | -61.8+/-0.2 | 17.0 | 0.30 | 88 | 14.28 | |
Average | - | -60.2+/-0.2 | - | -60.1+/-0.2 | - | 0.30 | 88 | 14.28 | Av: -60.2+/-0.2 Dead time not included |
10966-10969 | 163.0 | 37.0+/-1.0 | 158.9 | 37.8+/-1.0 | 99.0 | 0.00 | 88 | 14.28 | Hall C: 5.2% leak through |
10972-10973 | 163.0 | -64.6+/-0.3 | - | - | - | 0.30 | 0 | 14.28 | Hall C off |
10974 | 0.0 | - | - | - | - | 2.00 | 88 | 14.28 | no target |
The Hall C leakage was 5.2% at this slit position (14.28).
The full information is given
here .
The plot is given
here .
The final result with the leakage correction P=-60.2*1.052-37.0*0.052=-65.2+/-0.2
Pz=-65.2 +/- 0.2(stat) +/- 0.5(dilution) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -20.0o Wien angle)
(dead time correction NOT DONE)
The beam energy is 2.134 (acc). Injector angle is -72.0o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster ON.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
10986-10987 | 90.0 | - | - | - | - | 0.27 | 50 | 13.50 | |
10982-10985 | 23.0 | 75.9+/-0.2 | 18.1 | 73.5+/-0.2 | 0.5 | 0.27 | 50 | 13.50 | |
10988-10991 | 163.0 | 69.2+/-0.2 | 158.3 | 71.2+/-0.2 | 1.0 | 0.27 | 50 | 13.50 | |
Average | - | 72.6+/-0.2 | - | 72.4+/-0.2 | - | 0.27 | 50 | 13.50 | Av: 72.5+/-0.2 Dead time not included |
10992-10995 | 163.0 | -37.6+/-1.4 | - | - | - | 0.00 | 50 | 13.50 | Hall C: 2.0% leak through |
10996 | 0.0 | - | - | - | - | 5.00 | 50 | -1 | no target: 0.7 Hz coinc |
The Hall C leakage was 5.2% at this slit position (13.50).
The full information is given
here .
The plot is given
here .
The final result with the leakage correction P= 72.5*1.020+37.6*0.020= 74.7+/-0.2
Pz= 74.7 +/- 0.2(stat) +/- 0.5(dilution) +/- 3.0(syst-prelim) (1/2 wave plate IN, -72.0o Wien angle)
(dead time correction NOT DONE)
The beam energy is 2.842 (acc). Injector angle is +42.0o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster ON.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
11005-11006 | 90.0 | - | - | - | - | 0.30 | 73 | 14.15 | |
11001-11004 | 23.0 | 74.1+/-0.2 | 19.2 | 72.2+/-0.2 | 3.0 | 0.30 | 73 | 14.15 | |
11007-11010 | 163.0 | 73.5+/-0.2 | 159.4 | 75.0+/-0.2 | 7.0 | 0.30 | 31 | 14.15 | |
Average | - | 73.8+/-0.2 | - | 73.6+/-0.2 | - | 0.30 | 32 | 14.15 | Av: 73.7+/-0.2 Dead time not included |
11011-11014 | 163.0 | -41.0+/-1.4 | - | - | - | 0.00 | 33 | 14.15 | Hall C: 1.6% leak through |
11016-11017 | 23.0 | 80.2+/-0.3 | - | - | - | 0.30 | 0 | 14.15 | Hall C: no Hall C |
11018-11019 | 23.0 | 74.6+/-0.3 | - | - | - | 0.30 | 73 | 14.15 | |
11020-11023 | 23.0 | -41.0+/-1.0 | - | - | - | 0.00 | 73 | 14.15 | Hall C: 3.8% leak through |
11024 | 23.0 | 74.8+/-0.4 | - | - | - | 0.30 | 73 | 14.15 | |
11025 | 23.0 | 79.1+/-0.4 | - | - | - | 0.30 | 0 | 14.15 | |
11027 | 0.0 | - | - | - | - | 5.00 | 36 | -1 | no target: 0.8 Hz coinc |
The Hall C leakage was 3.8% at this slit position (14.15) at 73µA in Hall C and 1.6% at 32µA in Hall C.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction:
P= 72.2*1.038+41.0*0.038= 76.5+/-0.2 at 19.2o, 73µA in Hall C
P= 75.0*1.016+41.0*0.016= 76.9+/-0.2 at 159.4o, 32µA in Hall C
Pz= 76.7 +/- 0.2(stat) +/- 0.5(dilution) +/- 3.0(syst-prelim) (1/2 wave plate IN, 42.0o Wien angle)
(dead time correction NOT DONE)
The beam energy is 3.772 (acc). Injector angle is -29.2o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm), thr=250mV, raster ON.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
11034-11035 | 90.0 | - | - | - | - | 0.30 | 2.4 | 15.16 | |
11030-11034 | 22.5 | 78.8+/-0.2 | 18.7 | 76.9+/-0.2 | 0.2 | 0.30 | 2.4 | 15.16 | |
11036-11039 | 163.0 | 74.2+/-0.2 | 159.6 | 75.7+/-0.2 | 2.9 | 0.30 | 2.4 | 15.16 | |
Average | - | 76.5+/-0.2 | - | 76.3+/-0.2 | - | 0.30 | 2.4 | 15.16 | Av: 76.4+/-0.2 Dead time not included |
11040-11044 | 163.0 | -50.0+/-5.0 | - | - | - | 0.00 | 2.4 | 15.16 | Hall C: 0.12% leak through |
11045 | 0.0 | - | - | - | - | 5.00 | 2.4 | -1 | no target: 1.3 Hz coinc |
The Hall C leakage was 0.12% at this slit position (15.16) at 2.4µA in Hall C.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction:
P= 76.4*1.0012+50.0*0.0012= 76.5+/-0.2 at 2.4µA in Hall C
Pz= 76.5 +/- 0.2(stat) +/- 0.0(dilution) +/- 3.0(syst-prelim) (1/2 wave plate OUT, -29.2o Wien angle)
(dead time correction NOT DONE)
The beam energy is 1.1482 (acc). Injector angle is 30.2o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm), thr=250mV, raster OFF.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
11052-11053 | 90.0 | - | - | - | - | 0.20 | 50. | 14.22 | |
11048-11051 | 23.0 | 78.6+/-0.4 | 19.0 | 76.5+/-0.4 | 1.0 | 0.20 | 50. | 14.22 | Hall C partly at 30 and 77µA |
11054-11057 | 163.0 | 73.7+/-0.4 | 161.3 | 74.4+/-0.4 | 1.3 | 0.20 | 50. | 14.22 | Hall C 75µA 1/5 of run 11056 |
Average | - | 76.1+/-0.3 | - | 75.4+/-0.3 | - | 0.20 | 50. | 14.22 | Av: 75.8+/-0.3 Dead time not included |
11058-11059 | 163.0 | -34.0+/-5.0 | - | - | - | 0.00 | 75. | 14.22 | |
11062-11063 | 163.0 | -33.0+/-5.0 | - | - | - | 0.00 | 75. | 14.22 | Hall C: 0.6% leak through |
11064 | 0.0 | - | - | - | - | 5.00 | 75. | -1 | no target: 30 Hz coinc |
The Hall C leakage was 0.6% at this slit position (14.22) at 75µA in Hall C. At 50µA it should be 0.4%.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction:
P= 75.8*1.004+34.0*0.004= 76.2+/-0.3 at 50µA in Hall C
Pz= 76.2 +/- 0.3(stat) +/- 0.1(dilution) +/- 3.0(syst-prelim) (1/2 wave plate OUT, 30.o Wien angle)
(dead time correction NOT DONE)
The beam energy is 2.23591 (acc). Injector angle is 30.9o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm), thr=250mV, raster OFF.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
11073-11074 | 90.0 | - | - | - | - | 0.30 | 75. | 15.18 | |
11067-11072 | 23.0 | -78.1+/-0.2 | 19.0 | -76.0+/-0.2 | 7.0 | 0.30 | 75. | 15.18 | Hall C mostly at 75µA |
11075-11078 | 163.0 | -72.7+/-0.2 | 161.1 | -73.5+/-0.2 | 0.7 | 0.30 | 75. | 15.18 | |
Average | - | -75.4+/-0.1 | - | -74.7+/-0.1 | - | 0.30 | 75. | 15.18 | Av: -75.1+/-0.1 Dead time not included |
11079-11082 | 163.0 | 35.0+/-5.0 | - | - | - | 0.00 | 75. | 15.18 | Hall C: 0.9% leak through |
11083 | 0.0 | - | - | - | - | 5.00 | 75. | -1 | no target: 3.7 Hz coinc |
The Hall C leakage was 0.6% at this slit position (15.18) at 75µA in Hall C. At 50µA it should be 0.4%.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction:
P= 75.1*1.009+35.0*0.009= 76.1+/-0.1 at 75µA in Hall C
Pz= -76.1 +/- 0.1(stat) +/- 0.2(dilution) +/- 3.0(syst-prelim) (1/2 wave plate OUT, 30.9o Wien angle)
(dead time correction NOT DONE)
The beam energy is 4.4153 (acc). Injector angle is 60.3o, the 1/2 wave plate was OUT.
The collimator width was at max (4cm), thr=250mV, raster OFF.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
11092-11093 | 90.0 | - | - | - | - | 0.30 | 45. | 15.30 | |
11088-11091 | 23.0 | 75.2+/-0.2 | 20.1 | 73.8+/-0.2 | 2.0 | 0.30 | 45. | 15.30 | |
11094-11097 | 163.0 | 75.5+/-0.2 | 162.1 | 75.9+/-0.2 | 0.3 | 0.30 | 45. | 15.30 | |
Average | - | 75.4+/-0.1 | - | 74.8+/-0.1 | - | 0.30 | 45. | 15.30 | Av: 75.1+/-0.1 Dead time not included |
11098-11101 | 163.0 | -45.0+/-1.3 | - | - | - | 0.00 | 45. | 15.30 | Hall C: 0.4% leak through |
11102 | 0.0 | - | - | - | - | 5.30 | 75. | -1 | no target: 33.0 Hz coinc |
The Hall C leakage was 0.4% at this slit position (15.30) at 45µA in Hall C.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction:
P= 75.1*1.004+45.0*0.004= 76.1+/-0.1 at 45µA in Hall C
Pz= 75.6 +/- 0.1(stat) +/- 0.2(dilution) +/- 3.0(syst-prelim) (1/2 wave plate OUT, 60.3o Wien angle)
(dead time correction NOT DONE)
The beam energy is 3.32414 (acc). Injector angle is 43.6o, the 1/2 wave plate was IN.
The collimator width was at max (4cm), thr=250mV, raster OFF.
runs | Dial angle | Calculated angle | chi2 | laser | comments | ||||
---|---|---|---|---|---|---|---|---|---|
angle | Polarization % | angle | Polarization % | A, µA | C, µC | A slit | |||
11110-11111 | 90.0 | - | - | - | - | 0.30 | 40. | 15.10 | |
11106-11109 | 23.0 | 80.3+/-0.2 | 18.3 | 77.8+/-0.2 | 2.0 | 0.30 | 40. | 15.10 | |
11112-11115 | 163.0 | 75.2+/-0.2 | 160.5 | 76.2+/-0.2 | 2.0 | 0.30 | 40. | 15.10 | |
Average | - | 77.7+/-0.1 | - | 77.1+/-0.1 | - | 0.30 | 40. | 15.10 | Av: 77.4+/-0.1 Dead time not included |
11116-11119 | 163.0 | -40.0+/-3.0 | - | - | - | 0.00 | 40. | 15.10 | Hall C: 0.38% leak through |
The Hall C leakage was 0.4% at this slit position (15.10) at 40µA in Hall C.
The full information is given
here .
The plot is given
here .
The final result with the leakage correction:
P= 77.4*1.0038+40.0*0.0038= 77.8+/-0.1 at 40µA in Hall C
Pz= 77.8 +/- 0.1(stat) +/- 0.1(dilution) +/- 3.0(syst-prelim) (1/2 wave plate IN, 43.6o Wien angle)
(dead time correction NOT DONE)