January 27, 2011. Tilted Moller target alignment. Calculated foil angle is 19.95deg.
February 8, 2011. Power supply of the third Moller quad has been replased due to noise, see elog entry 1567253 .
S. Wood: test results for Moller quads power supply are in table.
E08-008: D-Threshold
Exclusive Study of Deuteron Electrodisintegration near Threshold
The beam energy is 3354.8MeV(accel), 549.0MeV(linac), 61.76MeV(injector).
Injector angle is -62.40o (+25.8o including flipper), the 1/2 wave plate was OUT.
Fast raster was ON. Beam was straight.
Moller energy lock was used. Beam energy was unstable. Beam energy fluctuation correction is needed.
Moller FSD problem was fixed(see elog 1569033 ).
Hall C Moller measurement result see hclog 220868 ).
12:45-13:30 Controlled access to fix moller rack power problem (see elog 347502 )
Runs 14985-14993: Moller Quad1 scan. There is a discrepancy between GEANT and measurement.
Runs 14994-15000: Moller Quad3 scan. No difference between GEANT and measurement.
Runs 15021-15023: beam charge asymmetry test.
Runs | Target | T.Pos. | Encoder | BOP | Polarization % | Cor.Polar. % | Chi2 | Comments |
15001-15006 | 5 | -1.1 | 1.367/1.013 | 8.0 | -83.49+/-0.36 | -84.06 | 1.8 | B.cur=0.5uA |
15007-15010 | 4 | -1.1 | 1.365/1.636 | 8.0 | -81.56+/-0.37 | -82.11 | 0.8 | B.cur=0.5uA |
15011-15016 | 3 | -1.1 | 1.368/2.232 | 8.0 | -80.78+/-0.21 | -81.38 | 8.2 | B.cur=0.4uA |
15017-15020 | 2 | -1.1 | 1.365/2.865 | 8.0 | -80.52+/-0.26 | -79.90 | 0.6 | B.cur=0.25uA |
15024-15025 | 2 | 0.0 | 1.770/2.933 | 8.0 | -82.17+/-0.38 | -81.74 | 0.7 | B.cur=0.25uA |
15026-15027 | 4 | 0.0 | 1.770/1.675 | 8.0 | -80.92+/-0.51 | -81.67 | 0.6 | B.cur=0.5uA |
15028-15029 | 5 | 0.0 | 1.768/1.043 | 8.0 | -83.38+/-0.54 | -83.99 | 0.1 | B.cur=0.5uA |
Average | 5 | - | - | - | -83.45+/-0.31 | -84.04 | 1.4 | - |
Average | 4 | - | - | - | -81.33+/-0.30 | -82.11 | 0.8 | - |
Average | 2 | - | - | - | -81.06+/-0.22 | -80.50 | 3.7 | - |
Average | 2-5 | - | - | - | -81.69+/-0.13 | -81.64 | 6.5 | - |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here.
For additional information see halog entry 347515 .
For the beam energy fluctuation see plot1 .
The final results:
Pz=(-81.64 +/- 0.13(stat) +/- 2.0(syst))%
The plots are given here .
The Moller Polarimeter commissioning.
The beam energy is 1721.3MeV(accel)
Injector angle is 90.00o -92.057o(Flipper), 0.0o(Wien), the 1/2 wave plate was IN.
Fast raster was OFF. Beam was straight.
Hall C energy lock was used.
Moller FSD problem was fixed(see elog 1655853 ).
Runs 15040-15046 Helicity 30Hz, 8 Windows, Quartet
Runs 15040-15045: beam charge asymmetry test.
Beam charge asymmetry was very unstable and the peaks were very wides (see plots below).
Run 15075 Beam charge asymmetry is back to normal (0.00071).
Runs 15048-15087 Helicity 960Hz
Runs 15050-15061: Moller Quad1 scan.
Runs 15064-15072: Moller Quad3 scan.
Runs | Target | Encoder | BOP | Polarization % | Comments |
15073-15074 | 4 | - | 8.0 | 58.73+/-0.42 | B.cur=0.3uA |
15075-15076 | 4 | - | 8.0 | 62.46+/-0.29 | B.cur=0.5uA |
15077-15078 | 4 | - | 8.0 | 62.25+/-0.24 | B.cur=0.7uA |
15079-15081 | 4 | - | 8.0 | 62.83+/-0.21 | B.cur=0.7uA double scan |
15082-15087 | 2 | - | 8.0 | 62.08+/-0.19 | B.cur=0.1uA |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here.
Plots with the beam charge asymmetry measurement results are shown below: