Beam charge asymmetry test.
'An artificial' beam charge asymmetry was measured in paralles with HRS DAQ.
There was no beam in the Hall
Runs 15090-15108 Helicity 30Hz
Runs 15109-15121 Helicity 1kHz
The Moller Log Book scan is given here .
The table with information is given here .
The plots with results are given here:
The beam energy is 2253.7MeV(accel), 548.0MeV(linac), 61.65MeV(injector).
Injector angle is -60.85o (90.0o, 88.71o flipper), the 1/2 wave plate was IN.
Fast raster was OFF. Beam was straight.
FADC and aperture detectors were not available (see elog
363797 ).
Beam tuning took ~1 hour.
Helicity frequency=960Hz, delay=8windows, pattern=Quartet.
14:55-15:34 (Runs 15193-15201) detector HV tuning.
Runs 15202-15207 beam polarization measurement. Target 2 was used.
Runs 15207-15210 - BCM calibration (Target 2)
Runs 15211-15220 - Q1 quad scan (Q3=1.15kG=47.25A)
Runs 15221-15229 - Q3 quad scan (Q1=2.2kG=106.87A).
Runs 15230-15231 - Beam polarization measurement.
Runs 15232-15237 - Target 4 at 4A BOP(low magnetic field) longitudinal scans.
Runs 15238-15241 - BCM calibration (Target 3).
Runs 15242-15247 beam charge asymmetry test.
Beam energy/current chart is shown on plot .
20:00: Moller target is parked, Moller target movement is unmasked. Moller dipole is OFF, quads settings are restored.
Runs | Target | B.cur, uA | Encoder | BOP | Polarization % | Chi2 | Comments |
15202-15207 | 2 | 0.11 | 1.358/2.906 | 8.0 | -79.88+/-0.24 | - | |
15208 | 2 | 0.08 | 1.358/2.906 | 8.0 | -79.10+/-0.69 | - | BCM calib. |
15209 | 2 | 0.06 | 1.358/2.906 | 8.0 | -76.35+/-0.80 | - | |
15210 | 2 | 0.15 | 1.358/2.906 | 8.0 | -80.35+/-0.54 | - | |
15211-15220 | 2 | 0.15 | 1.358/2.906 | 8.0 | - | - | Q1 scan |
15221-15229 | 2 | 0.15 | 1.358/2.906 | 8.0 | - | - | Q3 scan |
15230-15231 | 2 | 0.15 | 1.358/2.906 | 8.0 | -80.39+/-0.39 | - | |
15332 | 4 | 0.15 | 1.360/- | 4.0 | -80.36+/-0.75 | - | Long. scan |
15333 | 4 | 0.15 | 1.360/- | 4.0 | -80.06+/-0.76 | - | Long. scan |
15334 | 4 | 0.15 | 1.360/- | 4.0 | -80.47+/-0.76 | - | Long. scan |
15335 | 4 | 0.15 | 1.360/- | 4.0 | -80.07+/-0.77 | - | Long. scan |
15336 | 4 | 0.15 | 1.360/- | 4.0 | -79.40+/-0.75 | - | Long. scan |
15337 | 4 | 0.15 | 1.360/- | 4.0 | -78.49+/-0.70 | - | Long. scan |
15238-15239 | 3 | 0.15 | 1.387/2.283 | 8.0 | -80.50+/-0.45 | - | - |
15240 | 3 | 0.075 | 1.387/2.283 | 8.0 | -77.15+/-0.80 | - | BCM calib. |
15241 | 3 | 0.06 | 1.387/2.283 | 8.0 | -75.88+/-0.88 | - | - |
Average | 2 | - | - | - | -79.91+/-0.20 | 0.8 | Target 2 |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here .
The quads scan results are presented on plot .
Moller results for the beam charge asymetry test are: Set1 ,
Set2 and Set3 .
Full information about the beam charge asymmetry test is given in halog
363824 .
For additional information see halog entry 363148 .
The final results:
Pz=(-79.91 +/- 0.20(stat) +/- 1.7(syst))%
The plots are given here png , ps .
The beam energy is 2253.7MeV(accel), 548.0MeV(linac), 61.65MeV(injector).
Injector angle is -59.63o (90.0o, 88.72o flipper)
Runs 15252-15274 IHWP wave plate was IN. Passive HWP was IN
Runs 15275-15292 IHWP wave plate was OUT.
Fast raster was OFF. Beam was straight.
Helicity frequency=960Hz, delay=8windows, pattern=Quartet.
15:00-15:55 (Runs 15193-15201) detector HV tuning.
Runs 15259-15270 - Beam polarization measurement with IHWP wave plate IN. Target 2 was used.
Runs 15271-15274 - Bleed-through measurement, Hall A laser was OFF, Slit=15.15
Runs 15275-15282 - Beam polarization measurement with IHWP wave plate OUT.
Runs 15283-15286 - Bleed-through measurement, Hall A laser was OFF, Slit was open=-1.0
Runs 15288-15291 - Target 4 longitudinal scan (BOP=3A).
Run 15292 - Al target 4 (non polarized).
18:20 Moller target is parked, Moller target movement is unmasked. Moller dipole is OFF, quads settings are restored.
Runs | Target | B.cur, uA | Encoder | BOP | Polarization % | Chi2 | Comments |
15259-15270 | 2 | 0.1 | 0.808/2.906 | 8.0 | -80.43+/-0.46 | 0.9 | - |
15271-15274 | 2 | 0.0 | 0.808/2.906 | 8.0 | 2.5+/-44 | 1.1 | Hall A laser OFF, Slit=15.15 |
15275-15282 | 2 | 0.1 | 0.808/2.906 | 8.0 | +79.89+/-0.58 | 0.9 | - |
15283-15286 | 2 | 0.0 | 0.808/2.906 | 8.0 | -2.1+/-3.0 | 0.2 | Hall A laser OFF, Slit=-1.0 |
15287 | 4 | 0.1 | 1.668/0.259 | 8.0 | -68.51+/-0.33 | - | - |
15388-15291 | 4 | 0.1 | 1.668/- | 3.0 | - | - | Long. scan |
15292 | 6 | 0.1 | - | 8.0 | - | - | Asym=0.16+/-0.54 |
Average | 2 | - | - | 8.0 | 80.22+/-0.36 | 0.95 | Both IHWP |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here .
Plots with bleed-through measurement results are:
Slit=15.15 and Slit=-1.0
For additional information see halog entry 368402 .
The final results:
Pz=(-80.43 +/- 0.46(stat) +/- 1.7(syst))% IHWP=IN
Pz=(+79.89 +/- 0.58(stat) +/- 1.7(syst))% IHWP=OUT
Pz=(80.22 +/- 0.36(stat) +/- 1.7(syst))% Average
The plots are given here IHWP=IN , IHWP=OUT ,
Average .
The beam energy is 1711.MeV(accel), 416.MeV(linac), 46.69MeV(injector).
Injector angle is -49.60o (90.0o, 88.71o flipper)
IHWP wave plate was IN. Passive HWP was IN
Fast and slow rasters were OFF. Beam was straight.
Helicity frequency=960Hz, delay=8windows, pattern=Quartet.
The beam tunning Moller took ~1 hour.
Runs 15295-15303 - detector HV tuning.
Runs 15304-15313 - Beam polarization measurement. Target 2 was used.
Runs 15314-15317 - Bleed-through measurement, Hall A laser was OFF, Slit was open=-1.0
Runs 15318-15327 - Q1 quad scan.
Runs 15328-15335 - Q3 quad scan.
23:55 Moller target is parked, Moller target movement is unmasked. Moller dipole is OFF, quads settings are restored.
Runs | Target | B.cur, uA | Encoder | BOP | Polarization % | Chi2 | Comments |
15304-15313 | 2 | 0.1 | 0.800/2.921 | 8.0 | -88.52+/-0.30 | 1.3 | - |
15314-15317 | 2 | 0.0 | 0.800/2.921 | 8.0 | -3.3+/-2.6 | 0.6 | Hall A laser OFF, Slit=-1.0 |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here .
The plot with bleed-through measurement results is shown here .
The strip chart for the Moller measurement time is given here .
The plot is illustrated possible beam polarization correction for two different beam energies.
For additional information see halog entry 372508 .
The final results:
Pz=(-88.52 +/- 0.3(stat) +/- 1.7(syst))%
The plot with results is given here .
The beam energy is 1158MeV(accel), 548.MeV(linac), 61.65MeV(injector).
Injector angle is -70.0o (90.0o, -91.947o flipper)
IHWP wave plate was OUT. Passive HWP was IN
Fast and slow rasters were OFF. Beam was straight.
Helicity frequency=960Hz, delay=8windows, pattern=Quartet.
The beam tunning Moller took ~1.5 hour.
Runs 15338-15353 - Beam polarization measurement. Target 2 was used.
Runs 15354-15357 - Bleed-through measurement, Hall A laser was OFF, Slit was 14.0 (as experiment running).
Runs 15358-15369 - Q1 quad scan.
Runs 15370-15381 - Q3 quad scan.
23:55 Moller target is parked, Moller target movement is unmasked. Moller dipole is OFF, quads settings are restored.
Runs | Target | B.cur, uA | Encoder | BOP | Polarization % | Chi2 | Comments |
15338-15353 | 2 | 0.1 | 0.800/2.918 | 8.0 | 89.72+/-0.29 | 0.4 | - |
15314-15317 | 2 | 0.0 | 0.800/2.918 | 8.0 | -15+/-87 | - | Slit=14.0 |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here .
The plot with bleed-through measurement results is shown here .
For these beam energy, slit, helicity frequency
and bleed-through the number of events per helicity window is ~1.
The polarization measurement is senseless.
The strip chart for the Moller measurement time is given here .
For additional information see halog entry 378077 .
Quads scan result (comparizon with GEANT) is given here .
The final results:
Pz=(89.72 +/- 0.29(stat) +/- 1.7(syst))%
The plot with results is given here .
Spin Dance measurement
The beam energy is 2253.65MeV(accel), 548.MeV(linac), 61.65MeV(injector).
Injector angle at the beginning was -60.85o (90.0o, -91.947o flipper)
Fast and slow rasters were OFF. Beam was straight.
Helicity frequency=960Hz, delay=8windows, pattern=Quartet.
The beam tunning Moller took ~1.5 hour.
Runs | Target | B.cur, nA | Wien angle, o | BOP | Polarization % | Chi2 | Comments |
15382-15387 | 2 | 0.1 | -60.85 | 8.0 | -83.47+/-0.57 | 0.55 | IHWP=OUT PAS=OUT |
15388-15393 | 2 | 0.1 | -60.85 | 8.0 | -81.82+/-0.59 | 1.45 | IHWP=OUT PAS=IN |
15382-15393 | 2 | 0.1 | -60.85 | 8.0 | -82.67+/-0.41 | 1.28 | IHWP=OUT Average |
15394-15401 | 2 | 0.1 | -75.0 | 8.0 | -86.32+/-0.55 | 0.36 | IHWP=OUT PAS=IN |
15402-15408 | 2 | 0.1 | -20.0 | 8.0 | -43.82+/-0.51 | 0.81 | IHWP=OUT PAS=IN |
15409-15417 | 2 | 0.1 | +20.0 | 8.0 | +17.23+/-0.51 | 0.45 | IHWP=OUT PAS=IN |
15419-15430 | 2 | 0.1 | -60.2 | 8.0 | +80.40+/-0.45 | 1.0 | IHWP=IN PAS=OUT |
15431-15434 | 2 | 0.0 | -70.0 | 8.0 | -14+/-102 | - | Bleed-through Slit=-1.0 |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here .
The plot with bleed-through measurement results is shown here .
For these beam energy, slit, helicity frequency
and bleed-through the number of events per helicity window is ~1.
The polarization measurement is senseless.
For additional information see halog entry 382205 .
Spin dance result is given here .
The plots with Moller results for each Wien filter angle are given below: -60.85 o(1),
-60.85 o(2), -60.85 o(average),
-75.0 o, -20.0 o,
+20.0 o, -60.20 o,
The beam energy is 3349.65V(accel), 548.MeV(linac), 61.65MeV(injector).
Injector angle at the beginning was -60.20o (90.0o, -91.947o flipper)
Fast and slow rasters were OFF. Beam was straight.
Helicity frequency=960Hz, delay=8windows, pattern=Quartet.
The beam tunning Moller took ~1 hour.
Runs 15438-15467: IHWP=IN PAS=OUT
Runs 15438-15440: detector HV tune
Runs 15468-15501: IHWP=OUT PAS=IN
Runs 15469-15473: Bleed-through measurement, Hall A laser was OFF. Full open slit (-1).
Runs 15474-15489: Q1 scan (Q3=72.92A)
Runs 15490-15501: Q3 scan (Q1=96.82A)
Runs | Target | B.cur, nA | BOP | Polarization % | Chi2 | Comments |
15441-15468 | 2 | 0.05 | 8.0 | 83.59+/-0.31 | 0.74 | |
15469-15473 | 2 | 0.0 | 8.0 | -1.0+/-3.8 | 0.1 | Bleed-through Slit=-1.0 |
The Moller Log Book scan is given here .
The table with detailed information is given
here and here .
The plot with bleed-through measurement results is shown here .
For additional information see halog entry 385183 .
Plot with bleed-through measurement results is given on
png and ps .
The final result is:
Pz=(83.59 +/- 0.31(stat) +/- 1.7(syst))%
The plots are given here png , ps .