    keyword=Victor: NMR results

    Using wall thickness from the broken ice cone water cell and using Alexandre's number of 0.075 cm for the thickness for Victor. I recalculated the flux for the water cell and for Victor and obtained a NMR calibration constant

    Flux for Water cell: 38.95 cm^2
    Flux for Victor: 39.32 cm^2
    C_w: 0.06561 +/- 0.00178 mV/(amg*cm^2*%)
    Density for Victor: 8.08 amagats
    C_NMR: 4.80 %/mV
    S_He: 5.88 mV
    P_max: 28.2% (compared with 27.2% from EPR)

    Note: The flux for Victor may still change, when I get wall thickness numbers, but I wouldn't expect a large change now. I also will conduct some tests to check the flux model calculation for the ice cone cell compared with standard cells.