Reminder for shift takers
Here is list of computers and questions shift takers should know.
Please, make sure you know answers to all these questions.
- adaql2
- DAQ
- adaql1
- Online Replay
- hacsbc2
- Controls
- adaql8
- Shift Leader
- hapc7
- hapc5
- Scaler
- adaql3
- Nice for analysis
adaql2 - DAQ
Never run any application on adaql2 except DAQ, even using ssh to other computers
- CODA runcontrol
-
- Configure, Download, Start, End run (kcoda, startcoda)
- Select the GEN configuration
- Watch download process
- Watch the ROCs
- Check the event rate (~600 Hz at 8 µA with ³He target)
- Check the correspondence of run numbers in the datamon(DMON) and in the CODA runcontrol
- Watch the dead time (~12-15% at 8 µA with ³He target)
- Check prescale values (100000,80,1 for production).
- After you start new run with GEN DAQ
- Start a new run with HAPPEX DAQ on adaql1
- Check raster size with spot++ on adaql1
- Check the charge asymmetry with qasy on adaql1
- Check detectors with onlineGUI
- Thresholds
-
- Check thresholds ( 0: -320, 1: -25, 2: -145 for production)
- ROCs
-
- Check terminals connected to ROCs.
- How to reboot, troubleshoot and check ROC status?
adaql1 - DAQ
- HAPPEX DAQ
-
- Configure, Download, Start, End run (kcoda, startcoda)
- Watch download process
- Watch the ROCs
- Monitor the charge asymmetry. It should be <100ppm.
- onlineGUI
-
- Start the onlineGUI (At least 15000 events required in CODA file.)
- Monitor the detectors.
- spot++
-
- Start spot++ to check the raster.
- Each raster change should be logged using halog.
- qasy
-
- Start qasy to monitor charge asymmetry
hacsbc2 - Controls
- T2 rate
-
- Start EPICS stripchart of T2
- Monitor for spikes.
- BB_HV
-
- Start hvs (High Voltage Control Tool).
- Monitor high Voltages.
- Monitor BB DC leakage currents.
Approximate DC leakage currents
Tab | Row | Value |
S10 | L8.0 | -128 |
S10 | L8.1 | -131 |
S10 | L8.2 | -132 |
S13 | L9.0 | -76 |
S13 | L9.1 | -15 |
S13 | L9.2 | -123 |
S13 | L9.3 | -29 |
S13 | L9.4 | -131 |
S13 | L9.5 | -126 |
S13 | L9.6 | -75 |
S13 | L9.7 | -44 |
- Learn how to overcome the DC trip.
- ND_HV
-
- Run hvs.
- Check high Voltages on ND.
- Notify experts about noisy channels.
- Hall A Main Menu
-
- Start the Hall A Main Menu
- Start the beam monitoring screen.
- Start Hall A General Tools screen.
- Monitor the beam position, beam energy
- BPMAx=0.4±0.2 BPMAy=1.4±0.2
- BPMBx=0±0.1 BPMBy=0±0.1
- Check Fast Feed Back status.
- Start BigBite magnet screen (readback = 706.5)
adaql8 - Shift Leader
- BTA
-
- Fill Beam Time Accounting using bta.
- Log every change in running conditions using HALOG.
hapc7
- Monticello
-
- Monitor the Monticello screen.
- Monitor Fast Feedback status.
hapc5 - Scaler
- xscaler
-
- Start the xscaler.
- Watch trigger rates ( 1: 2MHz, 2: 1.8KHz, 3: 550Hz at 8 µA )
- ND rates
-
- Start the bighand.tcl monitor.
- Look for dead and hot channels.