************************** For NIM: ************************** From XZ: Need to add a table summarizing all kinematics including RES. From DW: Need all run-by-run deadtime correction for DIS (run-by-run values missing, uncertainties can be derived from the 100uA values) From DW: Need all run-by-run deadtime corrections for RES (values are in elog, but missing uncertainties). From DW: Overal electron rates for all DIS and RES - as suggested by Bob: should list overall rates for all DIS and RES to show that the deadtime is proportional to rates in the first order. From KP: Overall pion rates (can be pi/e ratio) for all DIS and RES - this is to be combined with the electron rate above. ************************** For the resonance paper ************************** From DW: Need Q2 and W of kine 7b to send to theorist for APV calculation (2 res theorists, J. Erler for C1,2) From DW: Need asymmetry results of Kine 7b; ************************** For the SOM ************************** ---------------------- in Section 3.3, RM/som_beamcorr.tex ---------------------- DW/RM: Dithering correction table for BPM individual values is for narrow or wide (Table 3)? Should we list also for resonances? DW/RM: Dithering correction table with the asymmetry results (Table 4), what are the correction errors for the wide path? What about resonances? ---------------------- in Section 3.4, RM/som_beam_pol.tex ---------------------- From DW: need separate values for Compton and Moller for DISs (Table 5); With DW: confirm Compton, Moller, and COmbined values for RESs (Table 6). ---------------------- in Section 3.5, KP/som_bpmcalib.tex ---------------------- From KP: Need bull's eye calibration ---------------------- in Section 3.6, KP/som_optics.tex ---------------------- From KP: need vertex calibration plot for Left DIS#1(Fig.11); -> Then update Table 7. From KP: For RES#7 and #7b, need to check if there was any solid target data (carbon hole, BeO, Al dummy etc), to improve the optics uncertainty. ---------------------- in Section 3.7, DW/som_q2.tex ---------------------- From DW: need comparison table (HAMC vs. data) of Q2 and x for DIS (in Table 8). ---------------------- in Section 3.8, XZ/som_allbg.tex ---------------------- From KP: need corrected contamination analysis for electrons in pion triggers -> Both NIM and SOM Table 9; From XZ: The above item will affect the pion asymmetry results, which further affects the positron background analysis and corrections to the electron asymmetry. From KP: Also need all contamination analysis for RES -> Table 10; From XZ: Once get Q2 and W from DW on RES#7b, will update Table 13; XZ/DW: double check AT on the right HRS was done at Q2=1.907 (Table 14); RM/XZ: Need to use duality for the Al endcap evaluation, so the point that our measured RES asymmetries agree with DIS formula within their stat uncertainties must be made somewhere prior. ---------------------- in Section 3.9, DW/som_radcor.tex ---------------------- From DW: Need beam depolarization effect for all RES kinematics (line 808-809, below Eq.(45)). From DW: What is the form factor used in the e-p and e-n elastic (part of the quasi-elastic) asymmetry evaluation (line 848-852)? From DW: "Currently the average of $e-p$ and $e-n$ asymmetries is taken as the quasi-elastic asymmetry. This will be corrected when we are ready for another round of HAMC simulations." -- has this been corrected?(the formula of A_d says yes, but please confirm). From DW: For the toy model of the resonances, how was sigma_dis calculated? Was it from PDF fits, or NMC fits (line 856-858)? From DW: Need radiative corrections for resonances -> Table 16. From DW: Need RES7b results -> Table 15.