1) Five scalers involved: scaler4 : happex scaler scaler6 : SIS3801, the first one from the left of the crate scaler7 : SIS3801, the second one from the left scaler8 : SIS3801, the third from left, newly added scaler9 : SIS3820, the first from left, different stype, also newly added 2) The copies of 100kHz pulser are plugged into: scaler4_0, scaler6_0, scaler6_16, scaler7_0, scaler7_26, scaler8_0, scaler9_0 3) 'scaler6_0VSev_num.pdf' is the readings in chan1 of scaler6 VS event number. This simply shows how the frequency (=readings/0.033) changed with time. 3) The other plots are the difference between two scalers VS the average readings of the two. (the numbers in both x axies and y axies are readings, rather than frequency) 4) Did not plan to draw plots like 'scaler6_0VSscaler4_0', because the plots above have already included the information these plots would like to show. Just my opinion. If really needs, I will add. 5) Since Roc23 is down now, which tells information about pair synchronization, we can not plot asymmetries right now. Will do once the Roc23 is repaired.