############################## LEFT PION-REJECTOR DETECTOR 1 ###################### Number of columns (x-stripes) and rows (y-stripes) 2 17 Crate, Slot, First, Last ADC channels of blocks 3 24 0 15 3 24 16 16 3 22 16 31 3 24 48 48 -1 0 0 0 Translation table from ADC hardware channel to logical channel number (starts at 1!) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 X,Y,Z coords of Preshower front plane in spectrom cs 0.0 0.0 3.75 - Meters Half of X, half of Y, full Z sizes of Preshower 1.275 0.325 0.15 - Meters Rotation angle of the Preshower plane 0.0 - Degrees x,y position of the center of block 1 1.20 0.1625 - Meters dx and dy block spacing -0.15 -0.325 - Meters Energy threshold for clusters to be considered 11.0 - MeV ADC pedestals 540 522 503 426 576 549 614 586 537 500 494 470 630 602 554 595 511 400 347 333 300 491 543 422 499 344 337 398 330 578 513 524 471 498 Energy calibration coefficients 1.96033 1.98353 1.97193 1.72834 1.84433 1.92553 1.82113 1.89073 1.79794 1.75154 1.73994 1.67034 1.71674 1.78634 1.64714 1.63554 1.78634 1.60074 1.51955 1.60074 1.44995 1.50795 1.61234 1.78634 1.47315 1.67034 1.53114 1.48475 1.60074 1.39195 1.47315 1.51955 1.56594 0.881568