2014/02/26: This is the first day we try to run the test in the new lab space. Mostly tried to reproduced the earlier result on the LHCb tile. Had to change the PMT HV (increase by 200V), replaced a PMT, etc. But at the end got nearly 22 ph.e. for MIP. 2014/02/27: First try on the Chinese hexagon tile. For comparison: LHCb(Russian) tile: 1.5cm thick, fiber embedded 3.5 turns (nearly 4 turns if also counting the straight portion); MIP response see single p.e. peak is around 26 for the russ tile and around 27 for the chinese tile. Based on the russ tile peak at 541 we expect the chinese tile peak at: 24/18*2.3/3.5*27/26*541=492 +/- 20 given the error on determining the s.p.e. peak. We measure 497 for the four hour run 1228. Thickness of russ=18/32" Thickness of chin=24/32" No. turns of russ=3.5 No. turns of chin=2.3