    User name adev

    Log entry time 06:47:01 on November 3, 2000

    Entry number 51395

    keyword=End_of_Run_1041
    ****************************
     Run Number: 1041
    End of Run Comment:
    Tar=absence,Type=Other,Lmom=2.6471,Rmom=2.735,Ene=4.602,Angle_R=30.593,Angle_L=31.759
    1 step of current calibration
    
    
    Time of run = 4.1161947 min
    Av. current (on 3x) = 24.342062 uA
    Av. current (on 1x) = 24.280517 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    5.9966  |    6.0118  |    6.0245
    up-down    (mC)|    0.2025  |    0.1722  |    0.2019
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |       978.9 /mC  |   23.829 Hz  |      5885  |     1   |       981.4 /mC
        2      |       876.4 /mC  |    0.000 Hz  |      5269  | 65535   |       878.7 /mC
        3      |      2004.9 /mC  |   48.803 Hz  |     12053  |     1   |      2010.0 /mC
        4      |    141789.6 /mC  |    0.053 Hz  |    852411  | 65535   |    142149.0 /mC
        5      |       427.2 /mC  |    0.000 Hz  |      2568  | 65535   |       428.2 /mC
        output                        61.598 Hz
    Av. deadtime from accepted triggers = 0.1525
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  24.150867  Hz     |    23.495596 Hz   |  23.828643 Hz
        2      |  20.891441  Hz     |    21.791592 Hz   |  21.33443 Hz
        3      |  48.784914  Hz     |    48.826273 Hz   |  48.803166 Hz
        4      |  3454.2946  Hz     |    3451.6406 Hz   |  3451.4524 Hz
        5      |  10.580848  Hz     |    10.215833 Hz   |  10.397953 Hz
        output |  0.0  Hz   |    0.0 Hz |    61.598 Hz
    Accepted triggers  =  15213.00000
     Time of run = 4.1161947 min
     Time of run h- = 2.0344238 min
     Time of run h+ = 2.0351237 min
     1-(sum of time hel + and -)/( run time) = 1.1333e-02
    Rate of Left Arm Pulser for electronic DT  = 10.175256
    Rate of Right Arm Pulser for electronic DT  = 0.0
    Rate of Left Arm Pulser&trig for electronic DT  = 10.163109
    Rate of Right Arm Pulser&trig for electronic DT  = 0.0
    Left Arm Electronic DT  = 0.0011937923
    Right Arm Electronic DT  = -1
    Rate of Left Strobe  = 6334.702
    Rate of Right Arm Strobe  = 6054.6497
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.228008  Hz         |    0.0 Hz        |  11.228008 Hz
          -        |  0.0  Hz        |    11.228008 Hz       |  11.232057 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0030149         |   0.0030179         | 0.0060979     
       upstream 3x |   0.0030150         |   0.0030180         | 0.0060979     
       upstream 10x|   0.0030286         |   0.0030317         | 0.0061255     
      downstream   |   0.0029148         |   0.0029177         | 0.0058954    
     downstream 3x |   0.0029298         |   0.0029328         | 0.0059257    
     downstream 10x|   0.0029288         |   0.0029318         | 0.0059236    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   4.97281530e-04 
       upstream 3x |   4.97265040e-04 
       upstream 10x|   5.11525830e-04 
      downstream   |   4.97213890e-04 
     downstream 3x |   5.11718350e-04 
     downstream 10x|   5.11892980e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1041 at Fri Nov  3 06:46:50 EST 2000
    Right Arm D1 momentum                    : 2.735
    Right Arm arm angle                      : 30.5926
    Left Arm D1 momentum                      : 2.6417
    Left Arm arm angle                        : 31.7552
    Tiefenbach Hall A energy                : 4602.2
    Right Arm arm mispointing (HPT)          : -1.60487
    Left Arm arm mispointing (HPT)            : 4.95483
    Right Arm Q1 power supply current        : 2056.6
    Right Arm Q1 momentum                    : 2.73508
    Right Arm Q1 gauss meter                 : -0.05133
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1177.15
    Right Arm Q2 momentum                    : 2.73522
    Right Arm Q2 gauss meter                 : 0.6183
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 972.544
    Right Arm D1 momentum                    : 2.735
    Right Arm D1 NMR                         : 1.01493
    Right Arm Q3 power supply current        : 1088.25
    Right Arm Q3 momentum                    : 2.73493
    Right Arm Q3 gauss meter                 : 0.488
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 1987.33
    Left Arm Q1 momentum                      : 2.64157
    Left Arm Q1 gauss meter                   : 0.16877
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1137.53
    Left Arm Q2 momentum                      : 2.64173
    Left Arm Q2 gauss meter                   : -0.5993
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 914.781
    Left Arm D1 momentum                      : 2.6417
    Left Arm D1 NMR                           : 0.977889
    Left Arm Q3 power supply current          : 1051.65
    Left Arm Q3 momentum                      : 2.64156
    Left Arm Q3 gauss meter                   : 0.5249
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.0343612
    Current on Unser monitor                : 1.08327
    Current on Upstream bcm                 : 0.0392205
    Current on Downstream bcm               : 0.0295019
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 0.00142881
    MBSY1c Hall A Beam energy               : 4615.33
    MBSY1c magnet current (amp)             : 192.523
    MBSY1c Bdl                              : 1.15176e+06
    MBSY3c Hall C Beam energy               : 2341.14
    Tiefenbach Hall A energy                : 4602.2
    Tiefenbach Hall C energy                : 2333.1
    Delta(E)/E width (MV_AI_DXWID)          : 1.76142
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0
    IPM1H04B.XPOS                           : 0
    IPM1H04B.YPOS                           : 0
    Right Arm Arm Collimator                 : 0.865186
    Left Arm Arm Collimator                   : 0.868604
     HacR_HPM_LVDT:VALr                     : -1113
     HacR_VPM_LVDT:VALr                     : -175
     HacR_HPE1313A:0_Ch58                   : -0.54248
     HacR_HPE1313A:0_Ch55                   : 22.3633
     HacR_HPE1313A:0_Ch54                   : -0.755371
     HacR_alignROLL                         : -0.274318
     HacR_alignPITCH                        : -0.0130542
     HacR_alignHPT                          : -1.60456
     HacL_HPM_LVDT:VALr                     : -7813
     HacL_VPM_LVDT:VALr                     : 664
     HacL_HPE1313A:0_Ch58                   : -0.174316
     HacL_HPE1313A:0_Ch55                   : 23.8281
     HacL_HPE1313A:0_Ch54                   : -0.248047
     HacL_alignROLL                         : 0.113566
     HacL_alignPITCH                        : -0.0897365
     HacL_alignHPT                          : 4.95508
    haBDSPOS                                 : 732013
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 24.5
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.33
    haH2_P_Exhaust_R                         : 22.46
    haH2_P_Fill_Bottle_R                     : 22.74
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.465
    haSC200_6_Sensor_1_R                     : 242.56
    haSC200_6_Sensor_2_R                     : 27.05
    haSC200_6_Sensor_3_R                     : 3.54
    haSC200_6_Sensor_4_R                     : 38.5
    haHe_Omega_DPG_Sensor_R                  : -0.029
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.12
    haITC502_4_Sensor_1_R                    : 123.4
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 56.3
    haITC502_5_Sensor_1_R                    : 77.23
    haITC502_5_Sensor_2_R                    : 69.69
    haITC502_5_Sensor_3_R                    : 150.9
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 25.78
    Right Arm Arm Collimator                 : 0.865186
    Left Arm Arm Collimator                   : 0.868604
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : 0
    Wien field                               : 0
    Laser attenuation Hall A                 : 90
    Laser power  Hall A                      : 100