• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Hansen

    Log entry time 08:06:43 on November11,2000

    Entry number 51865

    keyword=Shift Summary

    Starting shift with Q^2=4 data taking in progress, run 1213.

    2:10 Noticed FPP chamber tripped. Run 1215 is junk and end of run 1214 is bad.
    2:35 Recovered from FPP trip. Start run 1216.
    3:25 Beam dies. MCC wants to tune a cavity. 10 minutes ...
    3:42 Beam is back.
    3:50 Current is now only 45uA.
    5:15 Frequent beam trips during run 1218.
    5:45 More bad beam.
    6:05 Current is up to 48uA and more stable now.
    6:55 Several minutes of no beam during run 1219.

    Run#...Start...#events...Comments
    1213....23:46...1M
    1214....00:49...1M......FPP trip at end of run
    1215....02:11...0..........junk
    1216....02:35...1M
    1217....03:42...1M
    1218....04:51...1M
    1219....06:06...1M
    1220....07:15...

    Somewhat unstable beam. About 6.75M events collected.