    User name adev

    Log entry time 23:21:51 on November 13, 2000

    Entry number 52044

    keyword=End_of_Run_1294
    ****************************
     Run Number: 1294
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.607,Angle_R=51.44,Angle_L=19.345, stopped run to insert half-wavelength plate
    
    
    Time of run = 4.5361817 min
    Av. current (on 3x) = 36.294108 uA
    Av. current (on 1x) = 36.189027 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|    9.8496  |    9.8782  |    9.8954
    up-down    (mC)|    0.2838  |    0.2532  |    0.3028
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |       280.2 /mC  |    0.000 Hz  |      2768  | 65535   |       281.0 /mC
        2      |         0.0 /mC  |    0.000 Hz  |         0  | 65535   |         0.0 /mC
        3      |      8480.8 /mC  |  307.803 Hz  |     83775  |     1   |      8505.4 /mC
        4      |    856507.3 /mC  |    0.474 Hz  |   8460750  | 65535   |    858994.3 /mC
        5      |       278.5 /mC  |    0.000 Hz  |      2751  | 65535   |       279.3 /mC
        output                       293.382 Hz
    Av. deadtime from accepted triggers = 0.0483
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  10.496922  Hz     |    9.8863942 Hz   |  10.170081 Hz
        2      |  0.0  Hz     |    0.0 Hz   |  0.0 Hz
        3      |  308.37311  Hz     |    307.66756 Hz   |  307.80293 Hz
        4      |  31079.922  Hz     |    31118.295 Hz   |  31086.167 Hz
        5      |  10.430015  Hz     |    9.8343605 Hz   |  10.10762 Hz
        output |  0.0  Hz   |    0.0 Hz |   293.382 Hz
    Accepted triggers  =  79850.00000
     Time of run = 4.5361817 min
     Time of run h- = 2.2421387 min
     Time of run h+ = 2.241927 min
     1-(sum of time hel + and -)/( run time) = 1.1489e-02
    Rate of Left Arm Pulser for electronic DT  = 10.170081
    Rate of Right Arm Pulser for electronic DT  = 5.1879169
    Rate of Left Arm Pulser&trig for electronic DT  = 10.10762
    Rate of Right Arm Pulser&trig for electronic DT  = 5.1879169
    Left Arm Electronic DT  = 0.0061416185
    Right Arm Electronic DT  = 0.0
    Rate of Left Strobe  = 50757.171
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.268655  Hz         |    0.0 Hz        |  11.272329 Hz
          -        |  0.0  Hz        |    11.268655 Hz       |  11.268655 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0049355         |   0.0049412         | 0.0099915     
       upstream 3x |   0.0049420         |   0.0049476         | 0.0100048     
       upstream 10x|   0.0049628         |   0.0049684         | 0.0100468     
      downstream   |   0.0047953         |   0.0048008         | 0.0097077    
     downstream 3x |   0.0048170         |   0.0048223         | 0.0097516    
     downstream 10x|   0.0048132         |   0.0048187         | 0.0097440    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   5.77115840e-04 
       upstream 3x |   5.66251420e-04 
       upstream 10x|   5.63879490e-04 
      downstream   |   5.73149510e-04 
     downstream 3x |   5.49832460e-04 
     downstream 10x|   5.71019220e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1294 at Mon Nov 13 23:21:36 EST 2000
    Right Arm D1 momentum                    : 2.735
    Right Arm arm angle                      : 12.5075
    Left Arm D1 momentum                      : 3.8086
    Left Arm arm angle                        : 19.3443
    Tiefenbach Hall A energy                : 4602.19
    Right Arm arm mispointing (HPT)          : -0.950488
    Left Arm arm mispointing (HPT)            : 4.80829
    Right Arm Q1 power supply current        : 2056.64
    Right Arm Q1 momentum                    : 2.73512
    Right Arm Q1 gauss meter                 : -0.05133
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 1176.86
    Right Arm Q2 momentum                    : 2.73454
    Right Arm Q2 gauss meter                 : 0.6183
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 972.585
    Right Arm D1 momentum                    : 2.735
    Right Arm D1 NMR                         : 1.01492
    Right Arm Q3 power supply current        : 1088.19
    Right Arm Q3 momentum                    : 2.73478
    Right Arm Q3 gauss meter                 : 0.4881
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2865.52
    Left Arm Q1 momentum                      : 3.80885
    Left Arm Q1 gauss meter                   : 0.243
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1640.04
    Left Arm Q2 momentum                      : 3.80874
    Left Arm Q2 gauss meter                   : -0.8627
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1400.24
    Left Arm D1 momentum                      : 3.8086
    Left Arm D1 NMR                           : 1.41088
    Left Arm Q3 power supply current          : 1516.23
    Left Arm Q3 momentum                      : 3.80849
    Left Arm Q3 gauss meter                   : 0.7559
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 5.46724
    Current on Unser monitor                : 5.60209
    Current on Upstream bcm                 : 5.4858
    Current on Downstream bcm               : 5.44869
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 8.04126
    MBSY1c Hall A Beam energy               : 4615.32
    MBSY1c magnet current (amp)             : 192.523
    MBSY1c Bdl                              : 1.15176e+06
    MBSY3c Hall C Beam energy               : 2341.14
    Tiefenbach Hall A energy                : 4602.19
    Tiefenbach Hall C energy                : 2333.09
    Delta(E)/E width (MV_AI_DXWID)          : 1.08224
    IPM1C12.XPOS                            : -1.56742
    IPM1H04A.XPOS                           : 0.0463582
    IPM1H04A.YPOS                           : 0.755742
    IPM1H04B.XPOS                           : -0.0646211
    IPM1H04B.YPOS                           : 0.10094
    Right Arm Arm Collimator                 : 0.865576
    Left Arm Arm Collimator                   : 0.868652
     HacR_HPM_LVDT:VALr                     : -1581
     HacR_VPM_LVDT:VALr                     : -1683
     HacR_HPE1313A:0_Ch58                   : -0.561035
     HacR_HPE1313A:0_Ch55                   : 22.2168
     HacR_HPE1313A:0_Ch54                   : -0.847168
     HacR_alignROLL                         : -0.367099
     HacR_alignPITCH                        : 0.00413284
     HacR_alignHPT                          : -0.949369
     HacL_HPM_LVDT:VALr                     : -7727
     HacL_VPM_LVDT:VALr                     : 1924
     HacL_HPE1313A:0_Ch58                   : -0.115234
     HacL_HPE1313A:0_Ch55                   : 23.7793
     HacL_HPE1313A:0_Ch54                   : -0.158691
     HacL_alignROLL                         : 0.192786
     HacL_alignPITCH                        : -0.142136
     HacL_alignHPT                          : 4.80602
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 63
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 23.15
    haH2_P_Exhaust_R                         : 23.26
    haH2_P_Fill_Bottle_R                     : 23.63
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.584
    haSC200_6_Sensor_1_R                     : 242.28
    haSC200_6_Sensor_2_R                     : 25.33
    haSC200_6_Sensor_3_R                     : 3.29
    haSC200_6_Sensor_4_R                     : 39.46
    haHe_Omega_DPG_Sensor_R                  : -0.03
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 94.98
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 18.95
    haITC502_2_Sensor_2_R                    : 18.94
    haITC502_2_Sensor_3_R                    : 19
    haITC502_4_Sensor_1_R                    : 116.6
    haITC502_4_Sensor_2_R                    : 19
    haITC502_4_Sensor_3_R                    : 54.7
    haITC502_5_Sensor_1_R                    : 74.61
    haITC502_5_Sensor_2_R                    : 67.19
    haITC502_5_Sensor_3_R                    : 134.4
    haITC502_6_Sensor_1_R                    : 99.97
    haITC502_6_Sensor_2_R                    : 99.97
    haITC502_6_Sensor_3_R                    : 24.91
    Right Arm Arm Collimator                 : 0.865479
    Left Arm Arm Collimator                   : 0.868701
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -772.93
    Wien field                               : 22.498
    Laser attenuation Hall A                 : 149
    Laser power  Hall A                      : 100
    Half-wave plate (off=out)                : ON