Log entry time 06:21:07 on December 1, 2000
Entry number 52639
keyword=Start_Run_1538_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1538 at Fri Dec 1 06:20:55 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.71e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.114995
Right Arm Q2 momentum : 0.000267202
Right Arm Q2 gauss meter : 0.000593
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97461
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.207386
Right Arm Q3 power supply current : 0.233092
Right Arm Q3 momentum : 0.000585792
Right Arm Q3 gauss meter : 0.0002537
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24304
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.95
Left Arm Q2 momentum : 3.80852
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.31
Left Arm D1 momentum : 3.80861
Left Arm D1 NMR : 1.41089
Left Arm Q3 power supply current : 1516.17
Left Arm Q3 momentum : 3.80833
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 0.0394676
Current on Unser monitor : -2.61192
Current on Upstream bcm : 0.0406984
Current on Downstream bcm : 0.0382369
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00142881
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 4.9939
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.31
haSC200_6_Sensor_2_R : 29.72
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 40.08
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 206.4
haITC502_4_Sensor_2_R : 18.9
haITC502_4_Sensor_3_R : 154.9
haITC502_5_Sensor_1_R : 67.68
haITC502_5_Sensor_2_R : 67.45
haITC502_5_Sensor_3_R : 199.2
haITC502_6_Sensor_1_R : 99.97
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.77
Right Arm Arm Collimator : 0.865283
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1279
HacR_VPM_LVDT:VALr : -1707
HacR_HPE1313A:0_Ch58 : -0.564453
HacR_HPE1313A:0_Ch55 : 22.6562
HacR_HPE1313A:0_Ch54 : -0.833984
HacR_alignROLL : -0.35333
HacR_alignPITCH : 0.00674766
HacR_alignHPT : -1.29751
HacL_HPM_LVDT:VALr : -7442
HacL_VPM_LVDT:VALr : 1813
HacL_HPE1313A:0_Ch58 : -0.118652
HacL_HPE1313A:0_Ch55 : 23.5352
HacL_HPE1313A:0_Ch54 : -0.155273
HacL_alignROLL : 0.19507
HacL_alignPITCH : -0.139143
HacL_alignHPT : 4.48983
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5098
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2606
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -198.25
Wien field : 5.6245
Laser attenuation Hall A : 120
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88