Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 19:25:46 on December 1, 2000
Entry number 52656
keyword=Start_Run_1542_Tar=carbon,Type=Other,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1542 at Fri Dec 1 19:25:28 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.67e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.141044
Right Arm Q2 momentum : 0.00032773
Right Arm Q2 gauss meter : 0.0005778
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97603
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.71172
Right Arm Q3 power supply current : 0.249485
Right Arm Q3 momentum : 0.000626989
Right Arm Q3 gauss meter : 0.0002641
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.243
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.11
Left Arm Q2 momentum : 3.80889
Left Arm Q2 gauss meter : -0.8626
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.28
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.25
Left Arm Q3 momentum : 3.80855
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 28.7071
Current on Unser monitor : 25.0314
Current on Upstream bcm : 28.4716
Current on Downstream bcm : 28.9426
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 34.3577
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.03297
Radiator Encoder : 0.153846
haBDSPOS : 732010
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 59
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.5
haSC200_6_Sensor_2_R : 19.03
haSC200_6_Sensor_3_R : 3.19
haSC200_6_Sensor_4_R : 40.13
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 84.6
haITC502_4_Sensor_2_R : 19
haITC502_4_Sensor_3_R : 68.8
haITC502_5_Sensor_1_R : 62.79
haITC502_5_Sensor_2_R : 61.93
haITC502_5_Sensor_3_R : 202.4
haITC502_6_Sensor_1_R : 97.95
haITC502_6_Sensor_2_R : 99.97
haITC502_6_Sensor_3_R : 27.75
Right Arm Arm Collimator : 0.865332
Left Arm Arm Collimator : 0.86875
HacR_HPM_LVDT:VALr : -1328
HacR_VPM_LVDT:VALr : -1745
HacR_HPE1313A:0_Ch58 : -0.564941
HacR_HPE1313A:0_Ch55 : 22.7051
HacR_HPE1313A:0_Ch54 : -0.83252
HacR_alignROLL : -0.351794
HacR_alignPITCH : 0.00713068
HacR_alignHPT : -1.24353
HacL_HPM_LVDT:VALr : -7480
HacL_VPM_LVDT:VALr : 1768
HacL_HPE1313A:0_Ch58 : -0.116699
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.19529
HacL_alignPITCH : -0.140677
HacL_alignHPT : 4.52772
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5095
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2604
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 175
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88