User name adev
Log entry time 04:43:14 on December 2, 2000
Entry number 52692
keyword=Start_Run_1557_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1557 at Sat Dec 2 04:43:00 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.7e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.335946
Right Arm Q2 momentum : 0.000780603
Right Arm Q2 gauss meter : 0.0005901
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97681
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.999538
Right Arm Q3 power supply current : 0.214393
Right Arm Q3 momentum : 0.0005388
Right Arm Q3 gauss meter : 0.0002601
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.243
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.11
Left Arm Q2 momentum : 3.8089
Left Arm Q2 gauss meter : -0.8626
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.28
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.23
Left Arm Q3 momentum : 3.80848
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 43.2433
Current on Unser monitor : 41.8615
Current on Upstream bcm : 43.083
Current on Downstream bcm : 43.4036
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 87.809
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.15873
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.53
haSC200_6_Sensor_2_R : 17.63
haSC200_6_Sensor_3_R : 3.21
haSC200_6_Sensor_4_R : 40.16
haHe_Omega_DPG_Sensor_R : -0.035
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 94.98
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 77.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 67.3
haITC502_5_Sensor_1_R : 61.3
haITC502_5_Sensor_2_R : 59.89
haITC502_5_Sensor_3_R : 192.7
haITC502_6_Sensor_1_R : 95.53
haITC502_6_Sensor_2_R : 99.72
haITC502_6_Sensor_3_R : 27.4
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1345
HacR_VPM_LVDT:VALr : -1742
HacR_HPE1313A:0_Ch58 : -0.564941
HacR_HPE1313A:0_Ch55 : 22.8027
HacR_HPE1313A:0_Ch54 : -0.831543
HacR_alignROLL : -0.350634
HacR_alignPITCH : 0.00648427
HacR_alignHPT : -1.22517
HacL_HPM_LVDT:VALr : -7523
HacL_VPM_LVDT:VALr : 1773
HacL_HPE1313A:0_Ch58 : -0.116211
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.155762
HacL_alignROLL : 0.195509
HacL_alignPITCH : -0.140901
HacL_alignHPT : 4.57926
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5093
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.26
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 203
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88