User name adev
Log entry time 20:12:29 on December 2, 2000
Entry number 52740
keyword=Start_Run_1574_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1574 at Sat Dec 2 20:12:17 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 2.29e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.311836
Right Arm Q2 momentum : 0.000724581
Right Arm Q2 gauss meter : 0.0005712
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 1.97748
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.892482
Right Arm Q3 power supply current : 0.236063
Right Arm Q3 momentum : 0.00059326
Right Arm Q3 gauss meter : 0.0002543
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.24303
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.03
Left Arm Q2 momentum : 3.80872
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.29
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.22
Left Arm Q3 momentum : 3.80846
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 43.2135
Current on Unser monitor : 39.1505
Current on Upstream bcm : 42.7244
Current on Downstream bcm : 43.8394
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 86.3056
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01343
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.6
haSC200_6_Sensor_2_R : 17.32
haSC200_6_Sensor_3_R : 3.16
haSC200_6_Sensor_4_R : 40.16
haHe_Omega_DPG_Sensor_R : -0.032
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.17
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.1
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 60.89
haITC502_5_Sensor_2_R : 59.38
haITC502_5_Sensor_3_R : 185.6
haITC502_6_Sensor_1_R : 94.19
haITC502_6_Sensor_2_R : 97.79
haITC502_6_Sensor_3_R : 27.3
Right Arm Arm Collimator : 0.865381
Left Arm Arm Collimator : 0.86875
HacR_HPM_LVDT:VALr : -1360
HacR_VPM_LVDT:VALr : -1750
HacR_HPE1313A:0_Ch58 : -0.564941
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.831055
HacR_alignROLL : -0.35075
HacR_alignPITCH : 0.00706488
HacR_alignHPT : -1.20831
HacL_HPM_LVDT:VALr : 0
HacL_VPM_LVDT:VALr : 1770
HacL_HPE1313A:0_Ch58 : -0.116211
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.15625
HacL_alignROLL : 0.195141
HacL_alignPITCH : -0.141413
HacL_alignHPT : 4.60042
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5092
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2599
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 203
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88