Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 01:04:44 on December 4, 2000
Entry number 52835
keyword=Start_Run_1610_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1610 at Mon Dec 4 01:04:32 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018772
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.262
Right Arm Q2 momentum : 0.999754
Right Arm Q2 gauss meter : 0.22544
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00072
Right Arm D1 NMR : 0.371357
Right Arm Q3 power supply current : 397.973
Right Arm Q3 momentum : 1.00016
Right Arm Q3 gauss meter : 0.1778
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.49
Left Arm Q1 momentum : 3.80881
Left Arm Q1 gauss meter : 0.24299
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1640.09
Left Arm Q2 momentum : 3.80885
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.31
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.38
Left Arm Q3 momentum : 3.80887
Left Arm Q3 gauss meter : 0.7558
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 50.5334
Current on Unser monitor : 46.7749
Current on Upstream bcm : 51.1882
Current on Downstream bcm : 51.1029
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 50.6657
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.175824
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.71
haSC200_6_Sensor_2_R : 17.23
haSC200_6_Sensor_3_R : 3.22
haSC200_6_Sensor_4_R : 40.18
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.15
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.6
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.2
haITC502_5_Sensor_1_R : 60.71
haITC502_5_Sensor_2_R : 59.13
haITC502_5_Sensor_3_R : 169.9
haITC502_6_Sensor_1_R : 93.7
haITC502_6_Sensor_2_R : 97.25
haITC502_6_Sensor_3_R : 27.17
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.868701
HacR_HPM_LVDT:VALr : -1420
HacR_VPM_LVDT:VALr : -1771
HacR_HPE1313A:0_Ch58 : -0.563965
HacR_HPE1313A:0_Ch55 : 22.9492
HacR_HPE1313A:0_Ch54 : -0.827148
HacR_alignROLL : -0.345096
HacR_alignPITCH : 0.00500572
HacR_alignHPT : -1.14325
HacL_HPM_LVDT:VALr : -7575
HacL_VPM_LVDT:VALr : 1760
HacL_HPE1313A:0_Ch58 : -0.115234
HacL_HPE1313A:0_Ch55 : 24.0723
HacL_HPE1313A:0_Ch54 : -0.156738
HacL_alignROLL : 0.195507
HacL_alignPITCH : -0.14266
HacL_alignHPT : 4.63711
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2596
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 262
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88