User name adev
Log entry time 18:06:34 on December 4, 2000
Entry number 52892
keyword=Start_Run_1631_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1631 at Mon Dec 4 18:06:21 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.045
Right Arm Q1 momentum : 1.00015
Right Arm Q1 gauss meter : -0.018781
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.458
Right Arm Q2 momentum : 1.00021
Right Arm Q2 gauss meter : 0.22551
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00073
Right Arm D1 NMR : 0.371358
Right Arm Q3 power supply current : 398.061
Right Arm Q3 momentum : 1.00038
Right Arm Q3 gauss meter : 0.17782
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.42
Left Arm Q1 momentum : 3.80871
Left Arm Q1 gauss meter : 0.24301
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.89
Left Arm Q2 momentum : 3.80838
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.32
Left Arm D1 momentum : 3.80859
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.38
Left Arm Q3 momentum : 3.80887
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 44.9176
Current on Unser monitor : 40.4368
Current on Upstream bcm : 44.964
Current on Downstream bcm : 44.8712
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 84.8065
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.07692
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 61.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.73
haSC200_6_Sensor_2_R : 17.3
haSC200_6_Sensor_3_R : 3.24
haSC200_6_Sensor_4_R : 40.19
haHe_Omega_DPG_Sensor_R : -0.034
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.77
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 75.9
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.3
haITC502_5_Sensor_1_R : 60.75
haITC502_5_Sensor_2_R : 59.25
haITC502_5_Sensor_3_R : 165.9
haITC502_6_Sensor_1_R : 93.97
haITC502_6_Sensor_2_R : 97.5
haITC502_6_Sensor_3_R : 27.11
Right Arm Arm Collimator : 0.363867
Left Arm Arm Collimator : 0.868799
HacR_HPM_LVDT:VALr : -1424
HacR_VPM_LVDT:VALr : -1760
HacR_HPE1313A:0_Ch58 : -0.5625
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.825684
HacR_alignROLL : -0.344487
HacR_alignPITCH : 0.00442502
HacR_alignHPT : -1.14024
HacL_HPM_LVDT:VALr : -7585
HacL_VPM_LVDT:VALr : 1769
HacL_HPE1313A:0_Ch58 : -0.115234
HacL_HPE1313A:0_Ch55 : 24.1699
HacL_HPE1313A:0_Ch54 : -0.156738
HacL_alignROLL : 0.195065
HacL_alignPITCH : -0.143097
HacL_alignHPT : 4.65073
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2595
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 259
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88