User name adev
Log entry time 11:39:14 on December 7, 2000
Entry number 53075
keyword=Start_Run_1703_Tar=LH2-15cm,Type=Elastic,Lmom=3.8086,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=19.261
Beginning-of-run EPICS data for Run Number 1703 at Thu Dec 7 11:39:02 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.94
Right Arm Q1 momentum : 1.00001
Right Arm Q1 gauss meter : -0.018781
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.562
Right Arm Q2 momentum : 1.00045
Right Arm Q2 gauss meter : 0.22552
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.401
Right Arm D1 momentum : 1.00074
Right Arm D1 NMR : 0.371361
Right Arm Q3 power supply current : 397.871
Right Arm Q3 momentum : 0.999904
Right Arm Q3 gauss meter : 0.17785
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2865.52
Left Arm Q1 momentum : 3.80885
Left Arm Q1 gauss meter : 0.243
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1639.81
Left Arm Q2 momentum : 3.8082
Left Arm Q2 gauss meter : -0.8627
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1400.33
Left Arm D1 momentum : 3.8086
Left Arm D1 NMR : 1.41088
Left Arm Q3 power supply current : 1516.14
Left Arm Q3 momentum : 3.80827
Left Arm Q3 gauss meter : 0.7559
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 47.2371
Current on Unser monitor : 43.3358
Current on Upstream bcm : 47.196
Current on Downstream bcm : 47.2782
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 92.0946
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01832
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 63
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.41
haSC200_6_Sensor_2_R : 17.22
haSC200_6_Sensor_3_R : 3.06
haSC200_6_Sensor_4_R : 40.04
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.89
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.1
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 61
haITC502_5_Sensor_2_R : 59.43
haITC502_5_Sensor_3_R : 155.4
haITC502_6_Sensor_1_R : 94.39
haITC502_6_Sensor_2_R : 97.91
haITC502_6_Sensor_3_R : 26.92
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868896
HacR_HPM_LVDT:VALr : -1438
HacR_VPM_LVDT:VALr : -1714
HacR_HPE1313A:0_Ch58 : -0.563965
HacR_HPE1313A:0_Ch55 : 23.0469
HacR_HPE1313A:0_Ch54 : -0.829102
HacR_alignROLL : -0.347938
HacR_alignPITCH : 0.00577193
HacR_alignHPT : -1.1226
HacL_HPM_LVDT:VALr : -7604
HacL_VPM_LVDT:VALr : 1853
HacL_HPE1313A:0_Ch58 : -0.112793
HacL_HPE1313A:0_Ch55 : 24.2188
HacL_HPE1313A:0_Ch54 : -0.153809
HacL_alignROLL : 0.196906
HacL_alignPITCH : -0.144045
HacL_alignHPT : 4.66885
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5086
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : -5.2
Left Arm Scattering Angle : 19.2594
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 258
Laser power Hall A : 73
Half-wave plate (off=out) : ON
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88