Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 08:40:29 on December 8, 2000
Entry number 53124
keyword=Start_Run_1718_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1718 at Fri Dec 8 08:40:18 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=65535,ps2=65535,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.01
Right Arm Q1 momentum : 1.0001
Right Arm Q1 gauss meter : -0.018782
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.368
Right Arm Q2 momentum : 1
Right Arm Q2 gauss meter : 0.22555
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.086
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.886
Right Arm Q3 momentum : 0.999942
Right Arm Q3 gauss meter : 0.17786
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.49
Left Arm Q1 momentum : 3.35954
Left Arm Q1 gauss meter : 0.21442
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.68
Left Arm Q2 momentum : 3.35969
Left Arm Q2 gauss meter : -0.7616
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.13
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.28
Left Arm Q3 momentum : 3.359
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 48.9132
Current on Unser monitor : 45.7545
Current on Upstream bcm : 48.9016
Current on Downstream bcm : 48.9248
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 94.9159
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00611
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.2
haSC200_6_Sensor_2_R : 17.23
haSC200_6_Sensor_3_R : 3.01
haSC200_6_Sensor_4_R : 39.86
haHe_Omega_DPG_Sensor_R : -0.031
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.82
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.6
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 67.1
haITC502_5_Sensor_1_R : 61.24
haITC502_5_Sensor_2_R : 59.7
haITC502_5_Sensor_3_R : 157
haITC502_6_Sensor_1_R : 94.89
haITC502_6_Sensor_2_R : 98.44
haITC502_6_Sensor_3_R : 26.88
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868555
HacR_HPM_LVDT:VALr : -1406
HacR_VPM_LVDT:VALr : -1643
HacR_HPE1313A:0_Ch58 : -0.566895
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.840332
HacR_alignROLL : -0.359452
HacR_alignPITCH : 0.00866315
HacR_alignHPT : -1.15186
HacL_HPM_LVDT:VALr : -8179
HacL_VPM_LVDT:VALr : 1351
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 24.1211
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0822502
HacL_alignPITCH : -0.129994
HacL_alignHPT : 5.36859
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5088
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7673
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 266
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88