User name adev
Log entry time 22:08:44 on December 8, 2000
Entry number 53155
keyword=Start_Run_1729_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.616,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1729 at Fri Dec 8 22:08:29 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018776
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.314
Right Arm Q2 momentum : 0.999877
Right Arm Q2 gauss meter : 0.22552
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.087
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371089
Right Arm Q3 power supply current : 397.796
Right Arm Q3 momentum : 1.00025
Right Arm Q3 gauss meter : 0.17783
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.2142
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.7
Left Arm Q2 momentum : 3.35972
Left Arm Q2 gauss meter : -0.7616
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1193.13
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.44
Left Arm Q3 momentum : 3.3594
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 52.7835
Current on Unser monitor : 49.0317
Current on Upstream bcm : 52.7938
Current on Downstream bcm : 52.7732
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 98.2548
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 60.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.28
haSC200_6_Sensor_2_R : 17.2
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 39.93
haHe_Omega_DPG_Sensor_R : -0.03
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.08
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 61.02
haITC502_5_Sensor_2_R : 59.48
haITC502_5_Sensor_3_R : 153.5
haITC502_6_Sensor_1_R : 94.38
haITC502_6_Sensor_2_R : 97.87
haITC502_6_Sensor_3_R : 26.76
Right Arm Arm Collimator : 0.363818
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1398
HacR_VPM_LVDT:VALr : -1626
HacR_HPE1313A:0_Ch58 : -0.567871
HacR_HPE1313A:0_Ch55 : 22.8516
HacR_HPE1313A:0_Ch54 : -0.840332
HacR_alignROLL : -0.360059
HacR_alignPITCH : 0.00924364
HacR_alignHPT : -1.16047
HacL_HPM_LVDT:VALr : -8198
HacL_VPM_LVDT:VALr : 1359
HacL_HPE1313A:0_Ch58 : -0.129883
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0829225
HacL_alignPITCH : -0.129771
HacL_alignHPT : 5.38727
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5089
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7672
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 289
Laser power Hall A :
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88