User name adev
Log entry time 06:26:12 on December 9, 2000
Entry number 53180
keyword=Start_Run_1739_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1739 at Sat Dec 9 06:25:58 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 752.045
Right Arm Q1 momentum : 1.00015
Right Arm Q1 gauss meter : -0.01877
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.356
Right Arm Q2 momentum : 0.999975
Right Arm Q2 gauss meter : 0.22556
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.087
Right Arm D1 momentum : 1
Right Arm D1 NMR : 0.371088
Right Arm Q3 power supply current : 397.86
Right Arm Q3 momentum : 0.999878
Right Arm Q3 gauss meter : 0.17783
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21417
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.61
Left Arm Q2 momentum : 3.35953
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.69
Left Arm D1 momentum : 3.35931
Left Arm D1 NMR : 1.24417
Left Arm Q3 power supply current : 1337.47
Left Arm Q3 momentum : 3.35947
Left Arm Q3 gauss meter : 0.6671
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 55.4087
Current on Unser monitor : 52.1088
Current on Upstream bcm : 55.6566
Current on Downstream bcm : 55.1609
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 101.197
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00855
Radiator Encoder : 0.156288
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.38
haSC200_6_Sensor_2_R : 17.18
haSC200_6_Sensor_3_R : 3.04
haSC200_6_Sensor_4_R : 40.01
haHe_Omega_DPG_Sensor_R : -0.028
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.21
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.1
haITC502_4_Sensor_3_R : 66.6
haITC502_5_Sensor_1_R : 61.19
haITC502_5_Sensor_2_R : 59.63
haITC502_5_Sensor_3_R : 153.2
haITC502_6_Sensor_1_R : 94.55
haITC502_6_Sensor_2_R : 98.02
haITC502_6_Sensor_3_R : 26.76
Right Arm Arm Collimator : 0.363916
Left Arm Arm Collimator : 0.868408
HacR_HPM_LVDT:VALr : -1380
HacR_VPM_LVDT:VALr : -1660
HacR_HPE1313A:0_Ch58 : -0.565918
HacR_HPE1313A:0_Ch55 : 22.9004
HacR_HPE1313A:0_Ch54 : -0.838379
HacR_alignROLL : -0.357479
HacR_alignPITCH : 0.00776523
HacR_alignHPT : -1.18097
HacL_HPM_LVDT:VALr : -8205
HacL_VPM_LVDT:VALr : 1312
HacL_HPE1313A:0_Ch58 : -0.129395
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.282227
HacL_alignROLL : 0.0815266
HacL_alignPITCH : -0.12926
HacL_alignHPT : 5.39576
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.509
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7672
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 0
Laser attenuation Hall A : 287
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88