    User name adev

    Log entry time 03:47:09 on December 10, 2000

    Entry number 53235

    keyword=End_of_Run_1761
    ****************************
     Run Number: 1761
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
    
    
    Time of run = 51.993733 min
    Av. current (on 3x) = 48.755491 uA
    Av. current (on 1x) = 48.620635 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  151.6781  |  152.0988  |  151.2277
    up-down    (mC)|    2.3318  |    1.8613  |    2.7303
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6593428.7 /mC  |    1.786 Hz  | 1002852600  | 180000   |   6611716.5 /mC
        2      |    185243.4 /mC  |    1.806 Hz  |  28175298  |  5000   |    185757.2 /mC
        3      |      6396.3 /mC  |  311.856 Hz  |    972875  |     1   |      6414.1 /mC
        4      |    747431.9 /mC  |   18.221 Hz  | 113683490  |  2000   |    749505.0 /mC
        5      |       437.2 /mC  |    0.000 Hz  |     66496  | 65535   |       438.4 /mC
        output                       320.890 Hz
    Av. deadtime from accepted triggers = 0.0383
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  321474.44  Hz     |    321270.11 Hz   |  321465.86 Hz
        2      |  9136.0995  Hz     |    9130.4496 Hz   |  9031.6327 Hz
        3      |  311.90095  Hz     |    311.6849 Hz   |  311.85649 Hz
        4      |  36448.167  Hz     |    36423.226 Hz   |  36441.407 Hz
        5      |  21.395056  Hz     |    21.31927 Hz   |  21.315389 Hz
        output |  0.0  Hz   |    0.0 Hz |   320.890 Hz
    Accepted triggers  = 1001055.00000
     Time of run = 51.993733 min
     Time of run h- = 25.702882 min
     Time of run h+ = 25.702978 min
     1-(sum of time hel + and -)/( run time) = 1.1307e-02
    Rate of Left Arm Pulser for electronic DT  = 10.166289
    Rate of Right Arm Pulser for electronic DT  = 5.0579813
    Rate of Left Arm Pulser&trig for electronic DT  = 10.121092
    Rate of Right Arm Pulser&trig for electronic DT  = 5.0522114
    Left Arm Electronic DT  = 0.0044458458
    Right Arm Electronic DT  = 0.0011407567
    Rate of Left Strobe  = 60868.926
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.306491  Hz         |    0.0 Hz        |  11.306811 Hz
          -        |  0.0  Hz        |    11.306811 Hz       |  11.306811 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0755750         |   0.0755390         | 0.1528440     
       upstream 3x |   0.0756675         |   0.0756329         | 0.1530295     
       upstream 10x|   0.0754487         |   0.0754167         | 0.1525928     
      downstream   |   0.0744219         |   0.0743864         | 0.1505122    
     downstream 3x |   0.0747476         |   0.0747142         | 0.1511682    
     downstream 10x|   0.0740995         |   0.0740682         | 0.1498625    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -2.38230740e-04 
       upstream 3x |   -2.28684130e-04 
       upstream 10x|   -2.12109600e-04 
      downstream   |   -2.38561960e-04 
     downstream 3x |   -2.23468470e-04 
     downstream 10x|   -2.11247120e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1761 at Sun Dec 10 03:46:57 EST 2000
    Right Arm D1 momentum                    : 0.999999
    Right Arm arm angle                      : 12.5091
    Left Arm D1 momentum                      : 3.35931
    Left Arm arm angle                        : 23.7671
    Tiefenbach Hall A energy                : 4582.74
    Right Arm arm mispointing (HPT)          : -1.19415
    Left Arm arm mispointing (HPT)            : 5.41007
    Right Arm Q1 power supply current        : 751.87
    Right Arm Q1 momentum                    : 0.999914
    Right Arm Q1 gauss meter                 : -0.018772
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.468
    Right Arm Q2 momentum                    : 1.00023
    Right Arm Q2 gauss meter                 : 0.22558
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 343.087
    Right Arm D1 momentum                    : 0.999999
    Right Arm D1 NMR                         : 0.371088
    Right Arm Q3 power supply current        : 397.734
    Right Arm Q3 momentum                    : 0.999562
    Right Arm Q3 gauss meter                 : 0.17777
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.59
    Left Arm Q1 momentum                      : 3.35968
    Left Arm Q1 gauss meter                   : 0.2142
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.39
    Left Arm Q2 momentum                      : 3.35902
    Left Arm Q2 gauss meter                   : -0.7614
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.68
    Left Arm D1 momentum                      : 3.35931
    Left Arm D1 NMR                           : 1.24417
    Left Arm Q3 power supply current          : 1337.31
    Left Arm Q3 momentum                      : 3.35908
    Left Arm Q3 gauss meter                   : 0.6672
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 57.3117
    Current on Unser monitor                : 54.7611
    Current on Upstream bcm                 : 57.5724
    Current on Downstream bcm               : 59.1115
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 103.852
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.74
    Tiefenbach Hall C energy                : 2323.9
    Delta(E)/E width (MV_AI_DXWID)          : 2.12774
    IPM1C12.XPOS                            : 0.0021418
    IPM1H04A.XPOS                           : 0.334068
    IPM1H04A.YPOS                           : 0.819228
    IPM1H04B.XPOS                           : -0.0773138
    IPM1H04B.YPOS                           : 0.0730528
    Right Arm Arm Collimator                 : 0.363916
    Left Arm Arm Collimator                   : 0.868408
     HacR_HPM_LVDT:VALr                     : -1370
     HacR_VPM_LVDT:VALr                     : -1660
     HacR_HPE1313A:0_Ch58                   : -0.567383
     HacR_HPE1313A:0_Ch55                   : 22.9492
     HacR_HPE1313A:0_Ch54                   : -0.836426
     HacR_alignROLL                         : -0.355392
     HacR_alignPITCH                        : 0.00853154
     HacR_alignHPT                          : -1.19559
     HacL_HPM_LVDT:VALr                     : -8218
     HacL_VPM_LVDT:VALr                     : 1302
     HacL_HPE1313A:0_Ch58                   : -0.130371
     HacL_HPE1313A:0_Ch55                   : 23.9258
     HacL_HPE1313A:0_Ch54                   : -0.282715
     HacL_alignROLL                         : 0.0824807
     HacL_alignPITCH                        : -0.128897
     HacL_alignHPT                          : 5.41206
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 61
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.1
    haH2_P_Exhaust_R                         : 22.16
    haH2_P_Fill_Bottle_R                     : 22.58
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.599
    haSC200_6_Sensor_1_R                     : 242.33
    haSC200_6_Sensor_2_R                     : 17.13
    haSC200_6_Sensor_3_R                     : 3.02
    haSC200_6_Sensor_4_R                     : 39.98
    haHe_Omega_DPG_Sensor_R                  : -0.033
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 90.09
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.17
    haITC502_4_Sensor_1_R                    : 76.1
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 66.5
    haITC502_5_Sensor_1_R                    : 61.43
    haITC502_5_Sensor_2_R                    : 59.82
    haITC502_5_Sensor_3_R                    : 151.9
    haITC502_6_Sensor_1_R                    : 94.86
    haITC502_6_Sensor_2_R                    : 98.33
    haITC502_6_Sensor_3_R                    : 26.71
    Right Arm Arm Collimator                 : 0.363818
    Left Arm Arm Collimator                   : 0.868311
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 313
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : ON