    User name adev

    Log entry time 08:34:18 on December 10, 2000

    Entry number 53250

    keyword=End_of_Run_1767
    ****************************
     Run Number: 1767
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
    
    
    Time of run = 50.800488 min
    Av. current (on 3x) = 49.991678 uA
    Av. current (on 1x) = 49.853983 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  151.9564  |  152.3761  |  151.4719
    up-down    (mC)|    2.3285  |    1.8759  |    2.7404
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6591521.2 /mC  |    1.831 Hz  | 1004390300  | 180000   |   6609726.9 /mC
        2      |    184641.9 /mC  |    1.846 Hz  |  28135017  |  5000   |    185151.9 /mC
        3      |      6385.7 /mC  |  319.231 Hz  |    973026  |     1   |      6403.3 /mC
        4      |    748275.2 /mC  |   18.704 Hz  | 114019260  |  2000   |    750341.9 /mC
        5      |       433.7 /mC  |    0.000 Hz  |     66079  | 65535   |       434.9 /mC
        output                       328.437 Hz
    Av. deadtime from accepted triggers = 0.0386
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  329516.04  Hz     |    329381.48 Hz   |  329521.22 Hz
        2      |  9338.653  Hz     |    9339.1685 Hz   |  9230.5599 Hz
        3      |  319.53386  Hz     |    318.7142 Hz   |  319.23118 Hz
        4      |  37408.167  Hz     |    37400.248 Hz   |  37407.535 Hz
        5      |  21.837306  Hz     |    21.590049 Hz   |  21.679254 Hz
        output |  0.0  Hz   |    0.0 Hz |   328.437 Hz
    Accepted triggers  = 1001085.00000
     Time of run = 50.800488 min
     Time of run h- = 25.114193 min
     Time of run h+ = 25.112988 min
     1-(sum of time hel + and -)/( run time) = 1.1285e-02
    Rate of Left Arm Pulser for electronic DT  = 10.168537
    Rate of Right Arm Pulser for electronic DT  = 5.0619592
    Rate of Left Arm Pulser&trig for electronic DT  = 10.115388
    Rate of Right Arm Pulser&trig for electronic DT  = 5.0547414
    Left Arm Electronic DT  = 0.0052268181
    Right Arm Electronic DT  = 0.0014258863
    Rate of Left Strobe  = 62404.463
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.232832  Hz         |    0.0 Hz        |  11.23316 Hz
          -        |  0.0  Hz        |    11.232832 Hz       |  11.232832 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0757105         |   0.0756862         | 0.1531207     
       upstream 3x |   0.0758071         |   0.0757834         | 0.1533141     
       upstream 10x|   0.0755714         |   0.0755497         | 0.1528421     
      downstream   |   0.0745592         |   0.0745351         | 0.1507922    
     downstream 3x |   0.0748800         |   0.0748572         | 0.1514382    
     downstream 10x|   0.0742171         |   0.0741959         | 0.1501017    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -1.60505480e-04 
       upstream 3x |   -1.56342250e-04 
       upstream 10x|   -1.43593450e-04 
      downstream   |   -1.61642670e-04 
     downstream 3x |   -1.52266770e-04 
     downstream 10x|   -1.42844630e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1767 at Sun Dec 10 08:34:02 EST 2000
    Right Arm D1 momentum                    : 1
    Right Arm arm angle                      : 12.5091
    Left Arm D1 momentum                      : 3.35931
    Left Arm arm angle                        : 23.7671
    Tiefenbach Hall A energy                : 4582.76
    Right Arm arm mispointing (HPT)          : -1.19419
    Left Arm arm mispointing (HPT)            : 5.40738
    Right Arm Q1 power supply current        : 751.94
    Right Arm Q1 momentum                    : 1.00001
    Right Arm Q1 gauss meter                 : -0.01878
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.194
    Right Arm Q2 momentum                    : 0.999598
    Right Arm Q2 gauss meter                 : 0.22548
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 343.094
    Right Arm D1 momentum                    : 1
    Right Arm D1 NMR                         : 0.371089
    Right Arm Q3 power supply current        : 397.902
    Right Arm Q3 momentum                    : 0.999982
    Right Arm Q3 gauss meter                 : 0.17786
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.52
    Left Arm Q1 momentum                      : 3.35959
    Left Arm Q1 gauss meter                   : 0.21422
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.53
    Left Arm Q2 momentum                      : 3.35934
    Left Arm Q2 gauss meter                   : -0.7614
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.69
    Left Arm D1 momentum                      : 3.35931
    Left Arm D1 NMR                           : 1.24417
    Left Arm Q3 power supply current          : 1337.34
    Left Arm Q3 momentum                      : 3.35915
    Left Arm Q3 gauss meter                   : 0.6672
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 56.2517
    Current on Unser monitor                : 53.0064
    Current on Upstream bcm                 : 56.0554
    Current on Downstream bcm               : 56.4479
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 101.065
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.76
    Tiefenbach Hall C energy                : 2323.9
    Delta(E)/E width (MV_AI_DXWID)          : 2.12923
    IPM1C12.XPOS                            : -0.000252247
    IPM1H04A.XPOS                           : 0.328488
    IPM1H04A.YPOS                           : 0.735316
    IPM1H04B.XPOS                           : -0.084533
    IPM1H04B.YPOS                           : -0.0359726
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.868408
     HacR_HPM_LVDT:VALr                     : -1370
     HacR_VPM_LVDT:VALr                     : -1659
     HacR_HPE1313A:0_Ch58                   : -0.566895
     HacR_HPE1313A:0_Ch55                   : 22.9492
     HacR_HPE1313A:0_Ch54                   : -0.836914
     HacR_alignROLL                         : -0.355943
     HacR_alignPITCH                        : 0.00859734
     HacR_alignHPT                          : -1.19415
     HacL_HPM_LVDT:VALr                     : -8217
     HacL_VPM_LVDT:VALr                     : 1296
     HacL_HPE1313A:0_Ch58                   : -0.130371
     HacL_HPE1313A:0_Ch55                   : 24.0234
     HacL_HPE1313A:0_Ch54                   : -0.282715
     HacL_alignROLL                         : 0.0829225
     HacL_alignPITCH                        : -0.128461
     HacL_alignHPT                          : 5.4085
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 22.31
    haH2_P_Exhaust_R                         : 22.39
    haH2_P_Fill_Bottle_R                     : 22.8
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.596
    haSC200_6_Sensor_1_R                     : 242.3
    haSC200_6_Sensor_2_R                     : 17.13
    haSC200_6_Sensor_3_R                     : 3.02
    haSC200_6_Sensor_4_R                     : 39.96
    haHe_Omega_DPG_Sensor_R                  : -0.032
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 89.89
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 19
    haITC502_2_Sensor_2_R                    : 19
    haITC502_2_Sensor_3_R                    : 19.17
    haITC502_4_Sensor_1_R                    : 76
    haITC502_4_Sensor_2_R                    : 19.1
    haITC502_4_Sensor_3_R                    : 66.5
    haITC502_5_Sensor_1_R                    : 61.47
    haITC502_5_Sensor_2_R                    : 59.87
    haITC502_5_Sensor_3_R                    : 151.6
    haITC502_6_Sensor_1_R                    : 94.89
    haITC502_6_Sensor_2_R                    : 98.34
    haITC502_6_Sensor_3_R                    : 26.7
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.868408
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 326
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : ON