    User name adev

    Log entry time 19:55:39 on December 10, 2000

    Entry number 53282

    keyword=End_of_Run_1782
    ****************************
     Run Number: 1782
    End of Run Comment:
    Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
    
    
    Time of run = 54.143637 min
    Av. current (on 3x) = 46.6056 uA
    Av. current (on 1x) = 46.473359 uA
                   |   on 1x    |   on 3x    |   on 10x
    Av. charge (mC)|  150.9742  |  151.4038  |  150.0979
    up-down    (mC)|    2.3727  |    1.8668  |    2.7235
     Trigger   | Scaler/charge(3x)|Scaler/time/ps|  Scaler    | Prescale| Scaler/charge(1x)
        1      |   6584921.0 /mC  |    1.705 Hz  | 996982060  | 180000   |   6603658.5 /mC
        2      |    183365.1 /mC  |    1.709 Hz  |  27762181  |  5000   |    183886.9 /mC
        3      |      6424.2 /mC  |  299.401 Hz  |    972641  |     1   |      6442.4 /mC
        4      |    751433.7 /mC  |   17.511 Hz  | 113769920  |  2000   |    753571.9 /mC
        5      |       454.2 /mC  |    0.000 Hz  |     68765  | 65535   |       455.5 /mC
        output                       307.849 Hz
    Av. deadtime from accepted triggers = 0.0390
    Av. deadtime from gated scalers = 1.0000
     Trigger   |  Plus Helicity   |  Minus Helicity |  Sum 
        1      |  307060.75  Hz     |    306944.58 Hz   |  306894.19 Hz
        2      |  8654.7749  Hz     |    8649.0749 Hz   |  8545.843 Hz
        3      |  299.25662  Hz     |    299.75457 Hz   |  299.40145 Hz
        4      |  35036.803  Hz     |    35029.976 Hz   |  35021.02 Hz
        5      |  21.10799  Hz     |    21.344373 Hz   |  21.167461 Hz
        output |  0.0  Hz   |    0.0 Hz |   307.849 Hz
    Accepted triggers  = 1000083.00000
     Time of run = 54.143637 min
     Time of run h- = 26.767398 min
     Time of run h+ = 26.766325 min
     1-(sum of time hel + and -)/( run time) = 1.1265e-02
    Rate of Left Arm Pulser for electronic DT  = 10.166784
    Rate of Right Arm Pulser for electronic DT  = 5.0289074
    Rate of Left Arm Pulser&trig for electronic DT  = 10.113531
    Rate of Right Arm Pulser&trig for electronic DT  = 5.02429
    Left Arm Electronic DT  = 0.0052379799
    Right Arm Electronic DT  = 0.00091816123
    Rate of Left Strobe  = 58565.718
    Rate of Right Arm Strobe  = 0.0
       helicity    |  Gate on + and run  |  Gate on - and run  |  Gate on run 
          +        |  11.252477  Hz         |    0.0 Hz        |  11.252784 Hz
          -        |  0.0  Hz        |    11.252477 Hz       |  11.252477 Hz
     
        Signal     |  Gate on + and run  |  Gate on - and run  |  Gate on run  |
                   |     Charge   (C)    |     Charge   (C)    | Charge   (C)  
       upstream    |   0.0752434         |   0.0752172         | 0.1521605     
       upstream 3x |   0.0753289         |   0.0753040         | 0.1523372     
       upstream 10x|   0.0748938         |   0.0748716         | 0.1514597     
      downstream   |   0.0740702         |   0.0740442         | 0.1497878    
     downstream 3x |   0.0744051         |   0.0743812         | 0.1504704    
     downstream 10x|   0.0735467         |   0.0735252         | 0.1487362    
     
     
        Signal     |  Asymmetry
                   |           
       upstream    |   -1.74131970e-04 
       upstream 3x |   -1.65302530e-04 
       upstream 10x|   -1.48231830e-04 
      downstream   |   -1.75539990e-04 
     downstream 3x |   -1.60633070e-04 
     downstream 10x|   -1.46187000e-04 
     
    
    ****************************
    End-of-run EPICS data for Run Number 1782 at Sun Dec 10 19:55:26 EST 2000
    Right Arm D1 momentum                    : 1
    Right Arm arm angle                      : 12.5092
    Left Arm D1 momentum                      : 3.35931
    Left Arm arm angle                        : 23.767
    Tiefenbach Hall A energy                : 4582.76
    Right Arm arm mispointing (HPT)          : -1.20122
    Left Arm arm mispointing (HPT)            : 5.42128
    Right Arm Q1 power supply current        : 751.94
    Right Arm Q1 momentum                    : 1.00001
    Right Arm Q1 gauss meter                 : -0.018769
    Right Arm Q1 power supply polarity       : 0
    Right Arm Q2 power supply current        : 430.326
    Right Arm Q2 momentum                    : 0.999905
    Right Arm Q2 gauss meter                 : 0.2255
    Right Arm Q2 power supply polarity       : 0
    Right Arm D1 power supply current        : 343.093
    Right Arm D1 momentum                    : 1
    Right Arm D1 NMR                         : 0.371088
    Right Arm Q3 power supply current        : 397.844
    Right Arm Q3 momentum                    : 0.999838
    Right Arm Q3 gauss meter                 : 0.17784
    Right Arm Q3 power supply polarity       : 1
    Left Arm Q1 power supply current          : 2527.59
    Left Arm Q1 momentum                      : 3.35968
    Left Arm Q1 gauss meter                   : 0.2142
    Left Arm Q1 power supply polarity         : 1
    Left Arm Q2 power supply current          : 1446.44
    Left Arm Q2 momentum                      : 3.35912
    Left Arm Q2 gauss meter                   : -0.7615
    Left Arm Q2 power supply polarity         : 0
    Left Arm D1 power supply current          : 1192.69
    Left Arm D1 momentum                      : 3.35931
    Left Arm D1 NMR                           : 1.24417
    Left Arm Q3 power supply current          : 1337.58
    Left Arm Q3 momentum                      : 3.35898
    Left Arm Q3 gauss meter                   : 0.6672
    Left Arm Q3 power supply polarity         : 0
    Average current of the two cavities     : 0.033512
    Current on Unser monitor                : -2.32907
    Current on Upstream bcm                 : 0.0306239
    Current on Downstream bcm               : 0.0361556
    Upstream Cavity Coefficient             : 77
    Downstream Cavity Coefficient           : 78.9
     Current on IBC0L02 (source)            : 7.63702
    MBSY1c Hall A Beam energy               : 4592.25
    MBSY1c magnet current (amp)             : 191.553
    MBSY1c Bdl                              : 1.146e+06
    MBSY3c Hall C Beam energy               : 2329.44
    Tiefenbach Hall A energy                : 4582.76
    Tiefenbach Hall C energy                : 2323.97
    Delta(E)/E width (MV_AI_DXWID)          : 2.12594
    IPM1C12.XPOS                            : 0
    IPM1H04A.XPOS                           : 0
    IPM1H04A.YPOS                           : 0.847389
    IPM1H04B.XPOS                           : -0.157392
    IPM1H04B.YPOS                           : 0.0566956
    Right Arm Arm Collimator                 : 0.363916
    Left Arm Arm Collimator                   : 0.868457
     HacR_HPM_LVDT:VALr                     : -1365
     HacR_VPM_LVDT:VALr                     : -1657
     HacR_HPE1313A:0_Ch58                   : -0.566895
     HacR_HPE1313A:0_Ch55                   : 22.998
     HacR_HPE1313A:0_Ch54                   : -0.836426
     HacR_alignROLL                         : -0.354899
     HacR_alignPITCH                        : 0.00898051
     HacR_alignHPT                          : -1.20035
     HacL_HPM_LVDT:VALr                     : -8226
     HacL_VPM_LVDT:VALr                     : 1294
     HacL_HPE1313A:0_Ch58                   : -0.131348
     HacL_HPE1313A:0_Ch55                   : 23.9258
     HacL_HPE1313A:0_Ch54                   : -0.283203
     HacL_alignROLL                         : 0.0829225
     HacL_alignPITCH                        : -0.128024
     HacL_alignHPT                          : 5.41855
    haBDSPOS                                 : 5.354e+06
    haL1_Fan_frequency_R                     : 0
    haL2_Fan_frequency_R                     : 62
    haL3_Fan_frequency_R                     : 0
    haH2_P_Fill_Target_R                     : 21.7
    haH2_P_Exhaust_R                         : 21.65
    haH2_P_Fill_Bottle_R                     : 22.22
    haH2_DP_Fill_Exhaust_R                   : 0
    haD2_P_Fill_Target_R                     : 0
    haD2_P_Exhaust_R                         : 0
    haD2_P_Fill_Bottle_R                     : 0
    haD2_DP_Fill_Exhaust_R                   : 27.68
    haSC200_6_Sensor_1_R                     : 242.36
    haSC200_6_Sensor_2_R                     : 17.18
    haSC200_6_Sensor_3_R                     : 3.06
    haSC200_6_Sensor_4_R                     : 39.99
    haHe_Omega_DPG_Sensor_R                  : -0.033
    haITC502_1_Sensor_1_R                    : 94.98
    haITC502_1_Sensor_2_R                    : 89.74
    haITC502_1_Sensor_3_R                    : 94.98
    haITC502_2_Sensor_1_R                    : 18.68
    haITC502_2_Sensor_2_R                    : 18.67
    haITC502_2_Sensor_3_R                    : 18.71
    haITC502_4_Sensor_1_R                    : 76.3
    haITC502_4_Sensor_2_R                    : 18.7
    haITC502_4_Sensor_3_R                    : 66.8
    haITC502_5_Sensor_1_R                    : 61.54
    haITC502_5_Sensor_2_R                    : 59.89
    haITC502_5_Sensor_3_R                    : 155
    haITC502_6_Sensor_1_R                    : 95.03
    haITC502_6_Sensor_2_R                    : 98.51
    haITC502_6_Sensor_3_R                    : 26.67
    Right Arm Arm Collimator                 : 0.363867
    Left Arm Arm Collimator                   : 0.868457
    Wien angle                               : -6.99926
    Helicity Mode ON/OFF Random/Toggle       : OFF
    Wien BDL                                 : -203.2
    Wien field                               : 5.6245
    Laser attenuation Hall A                 : 100
    Laser power  Hall A                      : 73
    Half-wave plate (off=out)                : OFF