User name adev
Log entry time 04:53:27 on December 11, 2000
Entry number 53314
keyword=Start_Run_1796_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1796 at Mon Dec 11 04:53:14 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 751.87
Right Arm Q1 momentum : 0.999914
Right Arm Q1 gauss meter : -0.018771
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 430.36
Right Arm Q2 momentum : 0.999984
Right Arm Q2 gauss meter : 0.22551
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 343.086
Right Arm D1 momentum : 0.999998
Right Arm D1 NMR : 0.371087
Right Arm Q3 power supply current : 398.062
Right Arm Q3 momentum : 1.00039
Right Arm Q3 gauss meter : 0.17783
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.59
Left Arm Q1 momentum : 3.35968
Left Arm Q1 gauss meter : 0.21421
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.35
Left Arm Q2 momentum : 3.35891
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.3593
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.34
Left Arm Q3 momentum : 3.35914
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 58.3792
Current on Unser monitor : 54.2915
Current on Upstream bcm : 58.1621
Current on Downstream bcm : 58.5964
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 106.954
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.01099
Radiator Encoder : 0.153846
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.41
haSC200_6_Sensor_2_R : 17.17
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 40.08
haHe_Omega_DPG_Sensor_R : -0.033
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 90.01
haITC502_1_Sensor_3_R : 94.98
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.7
haITC502_5_Sensor_1_R : 61.6
haITC502_5_Sensor_2_R : 59.92
haITC502_5_Sensor_3_R : 157.1
haITC502_6_Sensor_1_R : 95.09
haITC502_6_Sensor_2_R : 98.56
haITC502_6_Sensor_3_R : 26.64
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868457
HacR_HPM_LVDT:VALr : -1367
HacR_VPM_LVDT:VALr : -1659
HacR_HPE1313A:0_Ch58 : -0.568848
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.837402
HacR_alignROLL : -0.356378
HacR_alignPITCH : 0.00942945
HacR_alignHPT : -1.19726
HacL_HPM_LVDT:VALr : -8219
HacL_VPM_LVDT:VALr : 1295
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 :
HacL_alignROLL : 0.0829225
HacL_alignPITCH : -0.128024
HacL_alignHPT : 5.41073
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5091
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.7671
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 295
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88