User name adev
Log entry time 12:08:42 on December 11, 2000
Entry number 53341
keyword=Start_Run_1805_Tar=LH2-15cm,Type=Elastic,Lmom=3.3593,Rmom=1.000,Ene=4.58,Angle_R=12.51,Angle_L=23.767
Beginning-of-run EPICS data for Run Number 1805 at Mon Dec 11 12:08:31 EST 2000
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
;
ps1=180000,ps2=5000,ps3=1,ps4=2000,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Right Arm Q1 power supply current : 0
Right Arm Q1 momentum : 0
Right Arm Q1 gauss meter : 1.34e-05
Right Arm Q1 power supply polarity : 0
Right Arm Q2 power supply current : 0.111845
Right Arm Q2 momentum : 0.000259883
Right Arm Q2 gauss meter : 0.0005924
Right Arm Q2 power supply polarity : 0
Right Arm D1 power supply current : 731.061
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.652979
Right Arm Q3 power supply current : 0.241721
Right Arm Q3 momentum : 0.000607478
Right Arm Q3 gauss meter : 0.0003079
Right Arm Q3 power supply polarity : 1
Left Arm Q1 power supply current : 2527.52
Left Arm Q1 momentum : 3.35959
Left Arm Q1 gauss meter : 0.21421
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1446.65
Left Arm Q2 momentum : 3.35961
Left Arm Q2 gauss meter : -0.7615
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1192.68
Left Arm D1 momentum : 3.35929
Left Arm D1 NMR : 1.24416
Left Arm Q3 power supply current : 1337.43
Left Arm Q3 momentum : 3.35937
Left Arm Q3 gauss meter : 0.6672
Left Arm Q3 power supply polarity : 0
Average current of the two cavities : 55.0318
Current on Unser monitor : 51.7757
Current on Upstream bcm : 54.8342
Current on Downstream bcm : 55.2293
Upstream Cavity Coefficient : 77
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 109.071
Beam energy : 4592.25
MBSY1c magnet current (amp) : 191.553
Radiator 5V Linear Supply : 5.00366
Radiator Encoder : 0.151404
haBDSPOS : 5.354e+06
haL1_Fan_frequency_R : 0
haL2_Fan_frequency_R : 62.5
haL3_Fan_frequency_R : 0
haSC200_6_Sensor_1_R : 242.4
haSC200_6_Sensor_2_R : 17.15
haSC200_6_Sensor_3_R : 3.07
haSC200_6_Sensor_4_R : 40.06
haHe_Omega_DPG_Sensor_R : -0.029
haITC502_1_Sensor_1_R : 94.98
haITC502_1_Sensor_2_R : 89.87
haITC502_1_Sensor_3_R : 0
haITC502_4_Sensor_1_R : 76.2
haITC502_4_Sensor_2_R : 19.2
haITC502_4_Sensor_3_R : 66.5
haITC502_5_Sensor_1_R : 61.39
haITC502_5_Sensor_2_R : 59.77
haITC502_5_Sensor_3_R : 152.1
haITC502_6_Sensor_1_R : 95.16
haITC502_6_Sensor_2_R : 98.66
haITC502_6_Sensor_3_R : 26.63
Right Arm Arm Collimator : 0.363965
Left Arm Arm Collimator : 0.868506
HacR_HPM_LVDT:VALr : -1395
HacR_VPM_LVDT:VALr : -1648
HacR_HPE1313A:0_Ch58 : -0.566406
HacR_HPE1313A:0_Ch55 : 22.998
HacR_HPE1313A:0_Ch54 : -0.836914
HacR_alignROLL : -0.355885
HacR_alignPITCH : 0.00808257
HacR_alignHPT : -1.1662
HacL_HPM_LVDT:VALr : -8221
HacL_VPM_LVDT:VALr : 1299
HacL_HPE1313A:0_Ch58 : -0.131348
HacL_HPE1313A:0_Ch55 : 23.9746
HacL_HPE1313A:0_Ch54 : -0.283203
HacL_alignROLL : 0.0820389
HacL_alignPITCH : -0.128024
HacL_alignHPT : 5.41562
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34
Right Arm Scattering Angle : 12.5089
Left Arm Angle Floor Angle : 24
Left Arm Angle Vernier : -3
Left Arm Scattering Angle : 23.767
Wien angle : -6.99926
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : -203.2
Wien field : 5.6245
Laser attenuation Hall A : 317
Laser power Hall A : 73
Half-wave plate (off=out) : OFF
Survey X offset bpmA : -0.32
Survey Y offset bpmA : -0.35
Survey X offset bpmB : -0.05
Survey Y offset bpmB : -0.88